Variable-Speed Bearing Fault Diagnosis for Conveyor Gearboxes

I study the fault diagnosis problem of bearings in conveyor drive gearboxes when the drive operates under time-varying speed. Belt conveyors are widely used in coal-fired power stations, and their drive trains are often subjected to variable load, impact load, and non-uniform material supply. These conditions force the pinion gears, shafts, and bearings inside the gearbox to operate with fluctuating rotational speed. Under such conditions, the vibration signal is non-stationary, and the conventional frequency spectrum becomes smeared. I find that the fault-related components of bearings are difficult to identify directly from a Fourier spectrum because the characteristic frequencies are not fixed. Instead, they move with the instantaneous shaft speed. Therefore, I focus on an order-tracking strategy that uses an estimated instantaneous rotational frequency without a tachometer. The core of my method is an improved multi-source ridge fusion algorithm that estimates the instantaneous rotational frequency from the time-frequency distribution of the gearbox vibration signal. Then I apply computed order tracking to extract bearing fault order features. The method is especially useful for pinion gears and their supporting bearings in conveyor gearboxes, because the pinion gears often dominate the time-frequency energy pattern and provide stable frequency references.

My motivation is practical. In a conveyor drive gearbox, the pinion gears and their bearings are key transmission components. A bearing fault can cause unexpected downtime, secondary damage to the pinion gears, and even interruption of the entire coal transport line. However, variable-speed operation makes the vibration signature of a faulty bearing change continuously. A traditional spectrum may show broad bands, frequency blur, and overlapping components from different pinion gears. I therefore develop a diagnosis strategy that first estimates the instantaneous rotational frequency from the vibration itself, and then converts the time-domain signal into an angle-domain pseudo-stationary signal. In the angle domain, the bearing fault orders become stable, and the influence of speed fluctuation is suppressed.

I use the term pinion gears frequently because the gearbox contains several meshing pairs. The pinion gears are not only mechanical components; they are also powerful sources of reference frequencies. The rotational frequency of the input shaft, the meshing frequency of the pinion gears, and the harmonic families of these components are related by fixed ratios. I exploit this relationship to extract multiple instantaneous frequency ridges from the time-frequency plane. These ridges are then fused to obtain a high-accuracy estimate of the input rotational frequency. This estimate is later scaled by the transmission ratio to obtain the rotational frequency of the shaft that carries the faulty bearing.

The main contributions of my work can be summarized as follows. First, I propose an improved multi-source ridge fusion algorithm that uses both ridge amplitude and ridge continuity. Second, I design a complete bearing fault diagnosis procedure for time-varying conveyor gearbox conditions. Third, I validate the procedure using experiments on a two-stage reduction gearbox with inner-ring, outer-ring, and rolling-element bearing faults. The results show that my improved fusion algorithm is more accurate and more robust than a traditional multi-source ridge fusion algorithm, especially when the pinion gears operate under strong transient speed changes.

Symbol Meaning
$$x(t)$$ Measured vibration signal
$$X(f,\tau)$$ Short-time Fourier transform of the vibration signal
$$\hat f_m(i)$$ The m-th extracted instantaneous frequency ridge
$$k_{1,m}$$ Ratio between the m-th characteristic frequency and the input rotational frequency
$$\hat f_{r1,m}(i)$$ Input rotational frequency estimated from the m-th ridge
$$f_{r1}(i)$$ Fused input rotational frequency
$$f_r$$ Rotational frequency of the faulty bearing shaft
$$O_{BPFI}$$ Inner-ring fault order
$$O_{BPFO}$$ Outer-ring fault order
$$O_{BSF}$$ Rolling-element fault order
$$n$$ Number of rolling elements
$$d_w$$ Rolling-element diameter
$$D_m$$ Pitch diameter
$$\alpha$$ Contact angle

In my formulation, the pinion gears provide a set of characteristic frequencies that are linearly related to the input rotational frequency. Let the input rotational frequency be $$f_{r1}$$. The characteristic frequency set of the gearbox can be written as

$$ \{ F_i \} = \{ F_r, F_z, F_h \}, \quad F_i = k_i f_{r1} $$

where $$F_r$$, $$F_z$$, and $$F_h$$ denote rotational frequency components, gear meshing frequency components, and modulation sidebands of the pinion gears, respectively. The coefficient $$k_i$$ is determined by the number of teeth, the transmission ratio, and the bearing geometry. Because the pinion gears and bearings are connected by the same kinematic chain, the bearing fault frequencies are also proportional to the rotational frequency of the shaft on which the bearing is mounted.

I first review the short-time Fourier transform, which I use to construct the time-frequency distribution. For a vibration signal $$x(t)$$, the short-time Fourier transform is

$$ X(f,\tau) = \int_{-\infty}^{\infty} x(t) h^*(t-\tau) e^{-j 2 \pi f t} dt $$

where $$h(t-\tau)$$ is the sliding window, $$\tau$$ is the time index, and $$^*$$ denotes complex conjugation. The magnitude of $$X(f,\tau)$$ forms the time-frequency distribution. In this distribution, the pinion gear meshing components and the shaft rotational harmonics appear as ridges that follow the speed fluctuation. I use a local peak search algorithm to extract several high-energy ridges from the time-frequency distribution. In my experiments, I extract four ridges because the pinion gears and the input shaft provide strong and stable references.

Let the extracted ridges be denoted by

$$ \{ \hat f_m \}, \quad m = 1,2,3,4 $$

For each ridge, I determine its characteristic frequency ratio with respect to the input rotational frequency. Then the input rotational frequency estimated from the m-th ridge is

$$ \hat f_{r1,m} = \frac{\hat f_m}{k_{1,m}} $$

If all extracted ridges were ideal, the four estimates would be identical. In reality, noise, modulation, and close components from different pinion gears cause local errors. A traditional multi-source ridge fusion algorithm uses statistical consistency to remove abnormal ridge points. It computes the mean and standard deviation of the four estimates, defines an anomaly interval, and selects or averages the acceptable points. A typical traditional fusion result can be expressed as

$$ f_{r1}^{trad}(i) = \begin{cases} f_{r1,m^*}(i), & \arg\min_m \Delta_m(i) \in [t_1,t_2] \\ \frac{1}{4}\sum_{m=1}^{4} \hat f_{r1,m}(i), & \text{otherwise} \end{cases} $$

where $$\Delta_m(i)$$ is a deviation measure of the m-th estimate at time index $$i$$. This traditional approach reduces noise to some extent, but it still has a weakness. When the pinion gears undergo rapid speed changes, the ridge points may deviate from the true frequency because of local noise. The algorithm may then choose an incorrect ridge point simply because it is statistically close to the temporary mean. The result is a local error in the estimated rotational frequency.

To overcome this limitation, I propose an improved multi-source ridge fusion algorithm. The key idea is that a correct ridge point should have two properties: it should be located at a time-frequency point with high energy, and it should be consistent with the continuity of the ridge. In other words, the amplitude of the time-frequency distribution and the rate of frequency change should both be considered. I define a weight for each ridge point as

$$ B_m(i) = T(t,\hat f_m(i))^2 \left[ \hat f_m(i) – \hat f_m(i-1) \right]^2 $$

where $$T(t,\hat f_m(i))$$ is the magnitude of the time-frequency distribution at the ridge point. Because the amplitude and the frequency change rate have different numerical scales, I introduce a quantization coefficient $$\zeta_m$$. The weighted fusion formula is then

$$ f_{r1}(i) = \frac{ \sum_{m=1}^{4} B_m(i) \hat f_{r1,m}(i) }{ \sum_{m=1}^{4} B_m(i) } $$

In practice, I compute the weight with a normalized amplitude term and a normalized frequency-change term. The improved fusion function can be written as

$$ f_{r1}(i) = \frac{ \sum_{m=1}^{4} \zeta_m T(t,\hat f_m(i))^2 \left[ \hat f_{r1,m}(i) – \hat f_{r1,m}(i-1) \right]^2 \hat f_{r1,m}(i) }{ \sum_{m=1}^{4} \zeta_m T(t,\hat f_m(i))^2 \left[ \hat f_{r1,m}(i) – \hat f_{r1,m}(i-1) \right]^2 } $$

The quantization coefficient is chosen so that the amplitude term and the frequency-change term are on the same order of magnitude. I use

$$ \zeta_m = \frac{ \max_i \left[ T(t,\hat f_m(i))^2 \right] }{ \max_i \left[ \hat f_{r1,m}(i) – \hat f_{r1,m}(i-1) \right]^2 } $$

Before fusion, I also determine a reliable starting point. If the four estimated input rotational frequencies coincide closely, the probability of a correct estimate is high. Therefore, I search for the starting index by minimizing the sum of absolute deviations from the mean:

$$ i_0 = \arg\min_i \sum_{m=1}^{4} \left| \hat f_{r1,m}(i) – \text{mean}\left( \hat f_{r1,m}(i) \right) \right| $$

Starting from $$i_0$$, I perform forward fusion to the end of the signal and backward fusion to the beginning. This procedure prevents a local abnormal starting point from contaminating the entire fusion result. The improved algorithm therefore combines energy information and continuity information, which makes it more robust than the traditional statistical fusion method when the pinion gears operate under fast variable-speed conditions.

After I obtain the input rotational frequency, I calculate the rotational frequency of the faulty bearing shaft by using the transmission ratio. If the faulty bearing is on the j-th shaft and the ratio between the input shaft and that shaft is $$\eta_j$$, then

$$ f_{rj} = \eta_j f_{r1} $$

For the conveyor gearbox in my study, the faulty bearing is located on the intermediate shaft. The input-to-intermediate ratio is used to scale the estimated input rotational frequency. This scaled frequency becomes the reference for order tracking.

I then apply computed order tracking. The order is defined as the number of vibration cycles per revolution of the reference shaft. For a bearing on the shaft with rotational frequency $$f_r$$, the inner-ring, outer-ring, and rolling-element fault frequencies are

$$ f_{BPFI} = \frac{n}{2} f_r \left( 1 + \frac{d_w}{D_m} \cos\alpha \right) $$

$$ f_{BPFO} = \frac{n}{2} f_r \left( 1 – \frac{d_w}{D_m} \cos\alpha \right) $$

$$ f_{BSF} = \frac{1}{2} f_r \left[ 1 – \left( \frac{d_w}{D_m} \cos\alpha \right)^2 \right] \frac{D_m}{d_w} $$

Because the order is the fault frequency divided by the reference rotational frequency, the corresponding fault orders are

$$ O_{BPFI} = \frac{f_{BPFI}}{f_r} = \frac{n}{2} \left( 1 + \frac{d_w}{D_m} \cos\alpha \right) $$

$$ O_{BPFO} = \frac{f_{BPFO}}{f_r} = \frac{n}{2} \left( 1 – \frac{d_w}{D_m} \cos\alpha \right) $$

$$ O_{BSF} = \frac{f_{BSF}}{f_r} = \frac{1}{2} \left[ 1 – \left( \frac{d_w}{D_m} \cos\alpha \right)^2 \right] \frac{D_m}{d_w} $$

These orders are constant regardless of speed fluctuation. Therefore, after angle-domain resampling, the bearing fault features appear at fixed orders. This is the central advantage of my method for variable-speed conveyor gearboxes and their pinion gears.

My complete diagnosis procedure is as follows. First, I acquire the gearbox vibration signal with an acceleration sensor. Second, I compute the short-time Fourier transform and obtain the time-frequency distribution. Third, I use local peak search to extract four high-energy instantaneous frequency ridges. Fourth, I determine the characteristic frequency ratios of the selected ridges. The ridges may correspond to the input rotational frequency, its second harmonic, its third harmonic, and the second-stage pinion gear meshing frequency. Fifth, I calculate the four input rotational frequency estimates from the four ridges. Sixth, I determine the starting point for fusion and apply the improved multi-source ridge fusion algorithm. Seventh, I scale the fused input rotational frequency by the transmission ratio to obtain the faulty bearing shaft rotational frequency. Eighth, I use computed order tracking to resample the vibration signal in the angle domain. Ninth, I calculate the order envelope spectrum and identify the bearing fault order.

Step Operation Purpose
1 Acquire gearbox vibration signal Obtain raw data from the conveyor drive
2 Compute short-time Fourier transform Build time-frequency distribution
3 Extract four instantaneous frequency ridges Capture pinion gear and shaft references
4 Determine frequency ratios Relate ridges to input rotational frequency
5 Calculate four rotational frequency estimates Create multi-source candidates
6 Find fusion starting point Avoid contamination by local anomalies
7 Apply improved multi-source ridge fusion Obtain accurate instantaneous rotational frequency
8 Scale by transmission ratio Obtain faulty bearing shaft rotational frequency
9 Apply computed order tracking Convert non-stationary signal to angle-domain signal
10 Compute order envelope spectrum Identify bearing fault order

I evaluate the method on a power transmission fault diagnosis test rig. The test rig contains a two-stage reduction gearbox. The input shaft, intermediate shaft, and output shaft are connected by pinion gears with fixed tooth numbers. The gearbox structural parameters are listed in the following table. The transmission ratios are determined by the tooth numbers of the pinion gears. I use these ratios to map the estimated input rotational frequency to the intermediate shaft, where the faulty bearing is mounted.

Gear Stage Input Shaft Teeth Intermediate Shaft Teeth Output Shaft Teeth Ratio
First stage 29 100 — $$i_1 = 0.29$$
Second stage — 36 90 $$i_2 = 0.4$$

The faulty bearing is a deep-groove ball bearing. Its geometry is given in the following table. I use these parameters to compute the expected fault orders. The contact angle is zero in this case. The number of rolling elements, the rolling-element diameter, and the pitch diameter determine the inner-ring, outer-ring, and rolling-element fault orders.

Parameter Value
Pitch diameter $$D_m$$ 38.51 mm
Rolling-element diameter $$d_w$$ 7.97 mm
Number of rolling elements $$n$$ 9
Contact angle $$\alpha$$ 0 degrees

With these parameters, the theoretical fault orders are

$$ O_{BPFI} = 5.43, \quad O_{BPFO} = 3.572, \quad O_{BSF} = 2.322 $$

These orders are calculated with respect to the rotational frequency of the intermediate shaft, because the faulty bearing is located on that shaft. The pinion gears on the intermediate shaft rotate at this frequency, and the bearing fault impact sequence is synchronized with this rotation. The gearbox characteristic frequency orders are listed below. The input shaft order is 3.448 when the intermediate shaft order is set to 1, because the input-to-intermediate ratio is 0.29.

Characteristic Frequency Theoretical Order with Respect to Intermediate Shaft
Input shaft rotational frequency $$f_{r1}$$ 3.448
Intermediate shaft rotational frequency $$f_{r2}$$ 1
Output shaft rotational frequency $$f_{r3}$$ 0.4
First-stage pinion gear meshing frequency $$f_{z1}$$ 100
Second-stage pinion gear meshing frequency $$f_{z2}$$ 36
Inner-ring fault order $$O_{BPFI}$$ 5.43
Outer-ring fault order $$O_{BPFO}$$ 3.572
Rolling-element fault order $$O_{BSF}$$ 2.322

For the inner-ring fault experiment, I set the motor output rotational frequency to follow a triangular three-trough fluctuation from 40 Hz to 38 Hz. The sampling frequency is 25600 Hz, and the sampling duration is 4.6 s. The theoretical input rotational frequency range is 38–40 Hz. The intermediate shaft rotational frequency range is 11.02–11.6 Hz. The output shaft rotational frequency range is 4.408–4.64 Hz. The first-stage pinion gear meshing frequency range is 1102–1160 Hz, and the second-stage pinion gear meshing frequency range is 396.72–417.6 Hz. The inner-ring fault frequency range is 59.839–62.988 Hz. I first inspect the ordinary spectrum and envelope spectrum. The spectrum shows energy around the input rotational frequency and its harmonics, as well as around the first-stage pinion gear meshing frequency. The envelope spectrum shows blurred components around the shaft rotational frequencies and the inner-ring fault band. Because of the speed fluctuation, the fault frequency is not a sharp line, and the traditional spectrum and envelope spectrum cannot reliably diagnose the bearing fault.

I then apply my method. The short-time Fourier transform produces a time-frequency distribution in which the pinion gear meshing components and shaft harmonics are visible. I extract four high-energy ridges. In the inner-ring fault experiment, the four ridges correspond to the input rotational frequency, the second harmonic of the input rotational frequency, the third harmonic of the input rotational frequency, and the second-stage pinion gear meshing frequency. Therefore, the ratio vector is

$$ k = [1, 2, 3, 10.44] $$

Using these ratios, I obtain four estimates of the input rotational frequency. I then apply the improved multi-source ridge fusion algorithm. I compare three rotational frequency curves: the curve from an angular velocity sensor, the curve from the traditional multi-source ridge fusion algorithm, and the curve from my improved algorithm. The improved curve almost coincides with the sensor curve. The traditional curve has noticeable local errors. This shows that the improved fusion algorithm is more accurate for the inner-ring fault signal.

Next, I scale the estimated input rotational frequency to the intermediate shaft and apply computed order tracking. The angle-domain resampling transforms the non-stationary vibration signal into a pseudo-stationary angle-domain signal. I calculate the order envelope spectrum. With the sensor-based reference, a clear peak appears at order 5.41, which is close to the theoretical inner-ring fault order 5.43. With the traditional fusion algorithm, the order envelope spectrum differs from the sensor-based result, and the peak at 5.41 is not clear. With my improved fusion algorithm, the order envelope spectrum matches the sensor-based result, and a distinct peak appears at 5.41. Therefore, I correctly diagnose the inner-ring fault.

For the outer-ring fault experiment, I set the motor output rotational frequency to follow a triangular three-trough fluctuation from 40 Hz to 35 Hz. The sampling frequency is 25600 Hz, and the sampling duration is 4.6 s. The input rotational frequency range is 35–40 Hz. The intermediate shaft rotational frequency range is 10.15–11.6 Hz. The output shaft rotational frequency range is 4.06–4.64 Hz. The first-stage pinion gear meshing frequency range is 1015–1160 Hz. The second-stage pinion gear meshing frequency range is 365.4–417.6 Hz. The outer-ring fault frequency range is 36.256–41.435 Hz. The ordinary spectrum and envelope spectrum do not show a clear bearing outer-ring fault line in this range. A component near 39.78 Hz appears in the envelope spectrum, but it is related to the input shaft rotational frequency rather than the outer-ring fault. Again, the speed fluctuation causes frequency blur and makes traditional analysis unreliable.

I apply the same diagnosis strategy. The short-time Fourier transform gives a time-frequency distribution with clear ridges from the pinion gears and shaft harmonics. I extract four ridges corresponding to the input rotational frequency, its second harmonic, its third harmonic, and the second-stage pinion gear meshing frequency. The ratio vector is again

$$ k = [1, 2, 3, 10.44] $$

I estimate the input rotational frequency using the improved fusion algorithm. In this experiment, both the traditional and improved algorithms produce rotational frequency curves close to the sensor curve, but the improved curve is smoother and has smaller local errors. I then scale the frequency to the intermediate shaft and apply computed order tracking. The order envelope spectra show a clear peak at order 3.54, which is close to the theoretical outer-ring fault order 3.572. The improved algorithm gives a more concentrated peak and a clearer fault feature than the traditional algorithm. Thus, the outer-ring fault is successfully diagnosed.

For the rolling-element fault experiment, I set the motor output rotational frequency to follow a trapezoidal three-trough fluctuation from 40 Hz to 36 Hz. The sampling frequency is 25600 Hz, and the sampling duration is 10 s. The input rotational frequency range is 36–40 Hz. The intermediate shaft rotational frequency range is 10.44–11.6 Hz. The output shaft rotational frequency range is 4.176–4.64 Hz. The first-stage pinion gear meshing frequency range is 1044–1160 Hz. The second-stage pinion gear meshing frequency range is 375.84–417.6 Hz. The rolling-element fault frequency range is 24.242–26.935 Hz. The ordinary spectrum and envelope spectrum do not provide a clear rolling-element fault feature in this range. The pinion gear meshing components and shaft harmonics dominate, and the bearing fault signature is obscured by speed fluctuation.

I apply my improved method to this rolling-element fault signal. The short-time Fourier transform shows the pinion gear and shaft harmonic ridges. I extract four ridges with the same physical interpretation: input rotational frequency, second harmonic, third harmonic, and second-stage pinion gear meshing frequency. The ratio vector remains

$$ k = [1, 2, 3, 10.44] $$

I estimate the input rotational frequency and fuse the four estimates using the improved algorithm. The resulting rotational frequency curve almost coincides with the sensor curve. The traditional fusion algorithm, in contrast, produces a curve with larger errors and even loses the original fluctuation pattern. I then scale the frequency to the intermediate shaft and apply computed order tracking. In the order envelope spectrum, a clear peak appears at order 2.34, which is close to the theoretical rolling-element fault order 2.322. The traditional algorithm does not show a clear peak at this order, but my improved algorithm does. Therefore, I successfully diagnose the rolling-element fault.

The three experiments demonstrate the effectiveness of my method. The inner-ring, outer-ring, and rolling-element faults are all diagnosed from variable-speed gearbox vibration signals. The traditional multi-source ridge fusion algorithm only works well for the inner-ring fault signal in my tests. For the outer-ring and rolling-element fault signals, the traditional algorithm produces larger rotational frequency errors and fails to reveal clear fault orders. My improved algorithm, which uses both ridge amplitude and ridge continuity, provides higher accuracy and better robustness. The pinion gears in the gearbox act as stable frequency references, and their meshing harmonics improve the multi-source fusion process.

Fault Type Theoretical Order Observed Order with Improved Method Diagnosis Result
Inner-ring fault 5.43 5.41 Successfully identified
Outer-ring fault 3.572 3.54 Successfully identified
Rolling-element fault 2.322 2.34 Successfully identified

I also compare the computational logic of the traditional and improved fusion algorithms. The traditional algorithm mainly depends on the statistical distribution of the four rotational frequency estimates. It removes abnormal points by an anomaly interval and averages the remaining points. The improved algorithm depends on the time-frequency energy and the local frequency change rate. It gives larger weight to ridge points that are both energetic and continuous. This difference is important when the pinion gears undergo rapid speed changes, because a ridge point may be statistically acceptable but physically inconsistent. By including the continuity term, I reduce the chance of selecting a false peak caused by noise or by a neighboring pinion gear harmonic.

Algorithm Main Criterion Strength Weakness
Traditional multi-source ridge fusion Statistical consistency of rotational frequency estimates Simple and effective under moderate noise Can select false ridge points during fast transients
Improved multi-source ridge fusion Ridge amplitude and frequency continuity Higher accuracy and robustness under variable speed Requires time-frequency distribution and weight normalization

From a practical point of view, my method does not require a tachometer. This is advantageous for conveyor drive gearboxes because installing a speed sensor on every shaft is often difficult, expensive, or impossible. The instantaneous rotational frequency is estimated directly from the vibration signal. The pinion gears and their meshing harmonics provide the necessary frequency references. The method is therefore suitable for retrofit applications in coal-fired power stations and other industrial conveyor systems.

I also note that the selection of the number of ridges can be adjusted. I use four ridges in my experiments because the four selected components have high energy and clear physical meaning. In other gearboxes, the number of pinion gears, the number of stages, and the bearing configuration may differ. More ridges can be used if they are reliable. Fewer ridges can be used if the time-frequency distribution is simple. The improved fusion formula can be extended to any number of ridges. The key requirement is that each ridge must have a known or identifiable ratio with respect to the input rotational frequency.

For the bearing fault order calculation, I rely on the bearing geometry and the shaft on which the bearing is mounted. The inner-ring fault order, outer-ring fault order, and rolling-element fault order are constants. This is why order tracking is so effective. Under variable speed, the fault frequency changes with time, but the fault order remains fixed. The computed order tracking algorithm uses the estimated rotational frequency to resample the signal at equal angle increments. After resampling, the bearing fault impacts are equally spaced in the angle domain. The order envelope spectrum then reveals the fault order as a sharp peak.

In my experiments, the ordinary spectrum and envelope spectrum failed to diagnose the outer-ring and rolling-element faults because the speed fluctuation spread the fault energy over a frequency band. The pinion gear meshing components and their sidebands also overlapped with the bearing fault band. The improved multi-source ridge fusion algorithm provided a reliable rotational frequency estimate, and the computed order tracking algorithm converted the non-stationary signal into a pseudo-stationary angle-domain signal. As a result, the fault orders became clear. This confirms that the combination of improved ridge fusion and order tracking is an effective solution for time-varying conveyor gearbox bearing diagnosis.

I summarize the main findings in the following table. The first finding is that the pinion gear meshing harmonics are strong and stable enough to serve as ridge references. The second finding is that the improved fusion algorithm outperforms the traditional algorithm when the speed profile contains sharp transitions. The third finding is that computed order tracking successfully extracts inner-ring, outer-ring, and rolling-element fault orders. The fourth finding is that the method works without a tachometer, which improves its practical applicability.

Finding Description
Pinion gear references The pinion gears and their harmonics provide reliable frequency ridges for rotational frequency estimation.
Improved fusion Amplitude and continuity weighting improves accuracy under rapid speed changes.
Order tracking Computed order tracking converts non-stationary signals into angle-domain signals and reveals fixed fault orders.
Tachometer-free operation The instantaneous rotational frequency is estimated from vibration alone, which is practical for conveyor gearboxes.

In conclusion, I propose an improved multi-source ridge fusion algorithm for instantaneous rotational frequency estimation and a complete bearing fault diagnosis strategy for conveyor drive gearboxes under time-varying conditions. The method uses the time-frequency distribution of the vibration signal, extracts multiple ridges related to the pinion gears and shaft harmonics, and fuses them with both amplitude and continuity weighting. The fused rotational frequency is then used by computed order tracking to extract bearing fault orders. I validate the method with inner-ring, outer-ring, and rolling-element fault experiments. The results show that the improved algorithm estimates the instantaneous rotational frequency more accurately and more robustly than the traditional algorithm. The bearing fault orders are successfully identified in all three cases. The pinion gears play a central role in the method because their meshing harmonics provide stable multi-source references. I believe the proposed strategy is a practical and effective tool for condition monitoring and fault diagnosis of conveyor gearbox bearings under variable-speed operation.

Scroll to Top