Bearing Fault Diagnosis in Time-Varying Conveyor Gearboxes

In this work, I investigate the fault diagnosis of bearings in conveyor drive gearboxes that operate under time-varying conditions. Belt conveyors are widely used in coal-fired power stations for coal transportation. Because the coal transport volume changes, the system is subjected to variable loads and impact loads. This inevitably leads to various unexpected faults in the drive gearbox. Bearings are key components in the transmission of a pinion gear system, and bearing faults are one of the main causes of gearbox failure. When the conveyor operates under variable-speed driving, the gearbox generates non-stationary vibration signals. As a result, traditional spectrum analysis can hardly extract fault features from the vibration signals. Therefore, an in-depth study of bearing fault diagnosis in gearboxes under time-varying conditions is of great significance for the operation and maintenance of belt conveyors.

The most effective way to solve the speed fluctuation problem is the order tracking analysis method based on rotational frequency. This method calculates the cumulative rotation angle from the extracted instantaneous rotational frequency information, performs equal-angle resampling of the vibration signal through the rotation angle, and then performs order analysis on the obtained angle-domain stationary signal to extract fault characteristic orders. Therefore, how to accurately estimate the instantaneous frequency (IF) has become a hot and difficult topic in the fault research of variable-speed gearboxes. To address the problem of low IF estimation accuracy under time-varying conditions, many scholars have proposed effective solutions. Some methods use boxplot theory to estimate time-frequency ridges, reducing human intervention and improving the reliability of IF ridge estimation. Others propose an adaptive directional time-frequency distribution IF estimation algorithm based on RANSAC. Many scholars also combine multiple methods to improve IF estimation of non-stationary signals and achieve fault feature extraction of rotating machinery. For example, the amplitude accumulation and squaring method is used to enhance the characteristic ridges of time-frequency distribution, and then ridge fusion is performed based on probability distribution to achieve IF estimation. A bearing variable-speed diagnosis method combining synchronous extraction transform and order tracking technology has also been proposed. At the same time, an improved method based on MOMEDA has been proposed, which calculates the time-domain interval of fault pulses according to the equal-angle distribution characteristics of pulses in the angle domain, eliminating the influence of variable speed. A variable-speed bearing fault diagnosis method based on linear chirplet transform with Rayleigh entropy has also been proposed. Another method uses an improved fruit fly optimization algorithm to optimize topic correlation analysis for cross-condition bearing fault diagnosis.

The above studies focus on rotational frequency IF estimation methods based on non-stationary single-component or multi-component signals for bearing fault diagnosis. However, the speed fluctuation characteristics of belt conveyors are more complex. In this article, I propose a fault diagnosis method for conveyor gearbox bearings under time-varying conditions. I estimate the instantaneous rotational frequency of the gearbox under time-varying conditions and use the computed order tracking (COT) algorithm to extract bearing fault characteristic order information. Through simulation and experiments, I verify that the proposed method optimizes the extraction effect of bearing fault features in conveyor gearboxes. Throughout this article, the term pinion gear is used to refer to the small driving gear in the gearbox, and the interaction between the pinion gear and the larger gear is considered in the characteristic frequency analysis.

In a gearbox, the vibration signal contains rich information about the pinion gear, the large gear, the shafts, and the bearings. The characteristic frequencies of the gearbox are related to the rotational frequency of the input shaft. The pinion gear meshing frequency and its harmonics, as well as the modulation sidebands, are linearly proportional to the input rotational frequency. This relationship is the foundation of the multi-source ridge fusion algorithm. By extracting multiple time-frequency ridges from the vibration signal, I can correct the rotational frequency and improve the accuracy of instantaneous rotational frequency estimation.

1. Theoretical Analysis

1.1 Traditional Multi-Source Ridge Fusion Algorithm

Short-Time Fourier Transform (STFT) is a powerful time-frequency analysis method and has been widely used to obtain the time-frequency representation (TFR) of vibration signals. In this work, I use STFT to obtain the time-frequency distribution (TFD) of the signal. For a signal \(x(t)\), its STFT can be expressed as:

$$ X(f,\tau) = \int_{-\infty}^{+\infty} x(t) h^*(t-\tau) e^{-j2\pi f t} dt $$

where \(X(f,\tau)\) represents the frequency component of the signal \(x(t)\) at time \(\tau\) and frequency \(f\), \(*\) denotes the complex conjugate, and \(h(t-\tau)\) is the sliding window.

In the vibration signal of a gearbox, the characteristic frequencies at each stage, such as the rotational frequency of each shaft, the meshing frequency of the pinion gear, its harmonics, and the modulation sidebands, have a certain linear proportional relationship with the input rotational frequency \(f_{r1}\). Therefore, the characteristic frequency set \(F_i\) of the gearbox vibration signal can be expressed as:

$$ F_i = \{F_r, F_z, F_h\} = \sum_i k_i f_{r1} $$

where \(F_r\), \(F_z\), and \(F_h\) are the rotational frequency component, the meshing frequency component of the pinion gear, and the modulation sideband of the meshing frequency, respectively. \(k_i\) is the frequency coefficient, which is determined by the number of gear teeth, the transmission ratio, and the characteristic parameters of the bearings.

According to the relationship between the gearbox characteristic frequencies and the rotational frequency \(f_{r1}\), the traditional multi-source ridge fusion algorithm uses multiple characteristic frequency time-frequency ridges to correct the rotational frequency and improve the accuracy of rotational frequency extraction. First, four time-frequency ridges with high energy are extracted from different frequency bands in the TFD of the gearbox vibration signal, denoted as \(\{\hat{f}_m\} = \{\hat{f}_1, \hat{f}_2, \hat{f}_3, \hat{f}_4\}\), providing a large amount of initial information for ridge fusion.

From the linear proportional relationship between all characteristic frequencies and the rotational frequency, the corresponding input rotational frequency of the gearbox can be determined by the characteristic frequency \(\hat{f}_m\):

$$ \hat{f}_{r1,m} = \frac{\hat{f}_m}{k_i} $$

where \(\hat{f}_{r1,m}\) is the rotational frequency calculated from the \(m\)-th time-frequency ridge \(\hat{f}_m\). It should be noted that there are errors in \(\hat{f}_m\) obtained from the TFD of the signal, so the rotational frequencies \(\hat{f}_{r1,m}\) determined by them are not exactly the same.

If the search result of \(\hat{f}_m\) is correct, then the standard deviation of the rotational frequencies \(\hat{f}_{r1,m}\) determined by them is close to 0. On the contrary, if the error of \(\hat{f}_m\) is large, the standard deviation is large. Therefore, the abnormal interval \([t_1, t_2]\) of \(\hat{f}_{r1,m}\) can be determined as:

$$ \sigma_i = \frac{1}{4} \sum_{m=1}^4 \left( \hat{f}_{r1,m}(i) – f_{ave}(i) \right)^2 $$

$$ t_1 = \arg \max_i \left( CPDF(\sigma_i) \right), \quad t_2 = \arg \max_i \left( CPDF(\sigma_i) \right) $$

where \(\sigma_i\) is the standard deviation, \(f_{ave}\) is the mean value of the four synchronized rotational frequencies, and \(CPDF(\sigma_i)\) represents the cumulative probability distribution of \(\sigma_i\). The final ridge fusion result is:

$$ f_{r,trad}(i) = \begin{cases} f_{r,m^*}(i), & \arg\min_m \sigma_m(i) \in [t_1, t_2] \\ \frac{1}{4} \sum_{m=1}^4 f_{r,m}(i), & \text{otherwise} \end{cases} $$

The traditional ridge fusion algorithm reduces noise interference to a certain extent and improves the accuracy of rotational frequency estimation. However, when the algorithm eliminates erroneous ridge points, it only relies on statistical principles. When the noise interference is severe, it is easy to select wrong ridge points.

1.2 Improved Multi-Source Ridge Fusion Algorithm

For the ridge extraction result \(\hat{f}_m\), the local error is caused by local extreme points generated by noise in the TFD. In the TFD, the distribution of characteristic frequencies at any time follows the law of the above equation, while noise is irregularly distributed. At a certain time \(t_0\), the IF ridge \(\hat{f}_m(t_0)\) deviates from the theoretical frequency under the interference of noise. However, other ridges at \(t_0\), \(\hat{f}_{m’}(t_0)\) with \(m’ \neq m\), are not necessarily disturbed because noise is random. Using \(\hat{f}_{m’}(t_0)\) to replace \(\hat{f}_m(t_0)\) can eliminate noise interference and improve the accuracy of rotational frequency estimation. However, without knowing the theoretical rotational frequency, it is impossible to judge whether a ridge point \(\hat{f}_m(t)\) is correct. To obtain a more accurate rotational frequency, I propose an improved multi-source ridge fusion algorithm. According to the IF ridge \(\hat{f}_m\) and the time-frequency distribution of the signal, the rotational frequency \(\hat{f}_{r1,m}\) is corrected.

At time \(t_0\), the frequencies of the four IF ridges \(\hat{f}_m(t_0), m=1,2,3,4\) correspond to a time-frequency point \((t_0, \hat{f}_m(t_0))\) in the TFD. The amplitude (energy) of the time-frequency point is \(T(t_0, \hat{f}_m(t_0))\). I assume that a correct ridge point should have the following characteristics: first, the time-frequency point corresponding to the ridge point has a large amplitude; second, the ridge has continuity. Based on these two characteristics, I construct a new multi-source ridge fusion function as follows:

$$ f_r(i) = \frac{\sum_{m=1}^4 \left[ \zeta_m T^2(t, \hat{f}_m(i)) (f_r(i) – f_r(i-1))^2 \right] \hat{f}_{r,m}(i)}{\sum_{m=1}^4 \left[ \zeta_m T^2(t, \hat{f}_m(i)) (f_r(i) – f_r(i-1))^2 \right]} $$

where \(\zeta_m\) is the quantization coefficient for the amplitude and frequency change rate, and its calculation expression is:

$$ \zeta_m = \frac{\max_i T^2(t, \hat{f}_m(i))}{\max_i (f_r(i) – f_r(i-1))^2} $$

Because the values of amplitude and frequency change rate in the TFD differ greatly, the quantization coefficient \(\zeta_m\) is introduced to unify the two physical quantities in the same order of magnitude. This ensures that the amplitude and frequency change rate jointly determine the ridge fusion result.

If a coefficient \(B_m\) is defined as:

$$ B_m = \zeta_m T^2(t, \hat{f}_m(i)) (f_r(i) – f_r(i-1))^2 $$

then the fusion function can be simplified as:

$$ f_r(i) = \frac{\sum_{m=1}^4 B_m \hat{f}_{r,m}(i)}{\sum_{m=1}^4 B_m} $$

Therefore, the new ridge fusion function is a weighted average function constructed according to the amplitude and change rate of the ridge, which better reflects the true ridge variation. When performing ridge fusion at time \(t_0\) according to the above equation, if the arbitrarily selected fusion starting point happens to be a point in the IF ridge mutation region, it may cause a large error in the result due to the influence of abnormal values. Therefore, the starting point of ridge fusion must be defined.

When the four estimated input rotational frequencies \(\hat{f}_{r1,m}\) coincide infinitely, the error between the obtained rotational frequency and the theoretical rotational frequency \(f_{r1}\) is the smallest. Based on this theory, I search for the starting point of ridge fusion, i.e., the point \(f_r(i_0)\), as shown below:

$$ i_0 = \arg\min_i \sum_{m=1}^4 \left| \hat{f}_{r1,m}(i) – \text{mean}(\hat{f}_{r1,m}(i)) \right| $$

where \(i_0\) is the index of the starting point of ridge fusion, and \(\text{mean}(\cdot)\) denotes the average. For a signal with a data length of \(N\), starting from point \(i_0\), I first fuse forward to \(i=N\), and then fuse backward to \(i=1\).

1.3 Bearing Fault Characteristic Frequency and Order Calculation Theory

The geometric structure of a rolling bearing is fundamental to understanding its fault characteristic frequencies. In a pinion gear transmission system, the bearing supports the rotating shaft and the pinion gear. The rotational frequency of the shaft where the bearing is located is denoted as \(f_{rb}\). The diameter of the rolling element is \(d_w\), the inner ring diameter is \(d\), the pitch diameter is \(D_m\), the outer ring diameter is \(D\), the contact angle is \(\alpha\), and the number of rolling elements is \(n\). The relationship is \(D_m = (D + d)/2\).

The fault characteristic frequencies of rolling bearings are calculated as follows. For the inner ring fault, the characteristic frequency is:

$$ f_{BPFI} = \frac{n}{2} f_{rb} \left( 1 + \frac{d_w}{D_m} \cos\alpha \right) $$

For the outer ring fault, the characteristic frequency is:

$$ f_{BPFO} = \frac{n}{2} f_{rb} \left( 1 – \frac{d_w}{D_m} \cos\alpha \right) $$

For the rolling element fault, the characteristic frequency is:

$$ f_{BSF} = \frac{D_m}{2 d_w} f_{rb} \left[ 1 – \left( \frac{d_w}{D_m} \cos\alpha \right)^2 \right] $$

In the COT algorithm, the order is defined as the number of cyclic vibrations per rotation of the rotating shaft, i.e., \(O = \text{number of cyclic vibrations} / \text{revolution}\). Therefore, when inner ring fault, outer ring fault, and rolling element fault occur in a rolling bearing, the fault characteristic orders are:

$$ O_{BPFI} = \frac{f_{BPFI}}{f_{rb}} = \frac{n}{2} \left( 1 + \frac{d_w}{D_m} \cos\alpha \right) $$

$$ O_{BPFO} = \frac{f_{BPFO}}{f_{rb}} = \frac{n}{2} \left( 1 – \frac{d_w}{D_m} \cos\alpha \right) $$

$$ O_{BSF} = \frac{f_{BSF}}{f_{rb}} = \frac{D_m}{2 d_w} \left[ 1 – \left( \frac{d_w}{D_m} \cos\alpha \right)^2 \right] $$

These order values are independent of the rotational speed and can be used as robust indicators for bearing fault diagnosis under variable-speed conditions. In the following sections, I will demonstrate how these orders are extracted and used for fault diagnosis in a pinion gear gearbox.

2. Fault Diagnosis Strategy for Conveyor Gearbox Bearings under Time-Varying Conditions

For the gearbox vibration signal, I use the improved multi-source ridge fusion algorithm to extract the instantaneous rotational frequency of the conveyor gearbox and to diagnose bearing faults. The specific steps are as follows:

  1. Use a vibration acceleration sensor to acquire the gearbox vibration signal \(z_b(t)\).
  2. Obtain the time-frequency distribution of the gearbox vibration signal using STFT, and use a local peak search algorithm to extract four IF ridges \(\hat{f}_m\) from the TFD.
  3. Determine the corresponding characteristic frequency proportional coefficients \(\{k_i\}\) of \(\{\hat{f}_m\}\), and then determine the four rotational frequencies \(\{\hat{f}_{r1,m}\}\) determined by the four IF ridges.
  4. Determine the starting point of ridge fusion using the equation for \(i_0\).
  5. Perform adaptive rotational frequency fusion using the improved multi-source ridge fusion function to obtain the final gearbox input rotational frequency estimate \(\hat{f}_{r1}\).
  6. According to the shaft index \(j_b\) of the bearing and the corresponding transmission ratio \(\eta_b\), determine the fault bearing rotational frequency \(f_{rb}\).
  7. Use the COT algorithm to obtain the pseudo-stationary signal \(z_b'(t)\) of the gearbox vibration signal \(z_b(t)\) through \(f_{ri}\).
  8. Take the bearing rotational frequency \(f_{rb}\) as the first order, calculate the order envelope spectrum of \(z_b'(t)\), and analyze the bearing fault.

The overall fault diagnosis strategy is summarized in Table 1. This strategy integrates the improved multi-source ridge fusion algorithm with the COT algorithm, enabling effective bearing fault diagnosis under time-varying speed conditions. The use of multiple ridges from the pinion gear meshing frequency and its harmonics ensures that the instantaneous rotational frequency is accurately estimated even when noise is present.

Table 1. Summary of the proposed fault diagnosis strategy.
Step Operation Key Formula/Parameter
1 Vibration signal acquisition \(z_b(t)\)
2 STFT and ridge extraction \(X(f,\tau)\), four IF ridges \(\hat{f}_m\)
3 Proportional coefficient determination \(k_i\), \(\hat{f}_{r1,m} = \hat{f}_m / k_i\)
4 Fusion starting point \(i_0 = \arg\min_i \sum |\hat{f}_{r1,m}(i) – \text{mean}|\)
5 Improved ridge fusion \(f_r(i) = \sum B_m \hat{f}_{r,m}(i) / \sum B_m\)
6 Bearing rotational frequency \(f_{rb} = \eta_b f_{r1}\)
7 COT resampling Angle-domain pseudo-stationary signal \(z_b'(t)\)
8 Order envelope spectrum analysis Fault characteristic orders \(O_{BPFI}\), \(O_{BPFO}\), \(O_{BSF}\)

3. Experimental Analysis

3.1 Experimental Setup

To verify the effectiveness of the proposed method in practical applications, I conducted experiments on a power transmission fault diagnosis comprehensive test bench (DDS) developed by SpectraQuest. The test bench includes a two-stage reduction gearbox. The gear parameters and transmission ratios are listed in Table 2. The pinion gear on the input shaft meshes with the large gear on the intermediate shaft, and the second-stage pinion gear on the intermediate shaft meshes with the large gear on the output shaft. The fault bearing is located on the intermediate shaft. The bearing model is Rexnord ER16K deep groove ball bearing. The specific parameters are listed in Table 3. A vibration acceleration sensor is placed on the gearbox housing to measure the vibration signal.

Table 2. Structural parameters of the experimental gearbox.
Gear Stage Input Shaft Intermediate Shaft Output Shaft
First stage 29 (pinion gear) 100 —
Second stage — 36 (pinion gear) 90
Transmission ratio 1 \(i_1 = 0.29\) \(i_2 = 0.4\)
Table 3. Parameters of the ER16K bearing.
Pitch diameter (mm) Roller diameter (mm) Number of rollers Contact angle (°)
38.51 7.97 9 0

Using the bearing parameter formulas, the fault characteristic orders for the inner ring, outer ring, and rolling element faults of the experimental bearing are calculated as \(O_{BPFI} = 5.43\), \(O_{BPFO} = 3.572\), and \(O_{BSF} = 2.322\), respectively. These orders are defined with respect to the rotational frequency of the shaft where the fault bearing is located. The fault bearing is on the intermediate shaft, so the transmission ratio between the gearbox input shaft and the fault bearing shaft is \(f_{r2} = 0.29 f_{r1}\). The theoretical characteristic orders of the experimental gearbox are listed in Table 4.

Table 4. Theoretical characteristic orders of the experimental gearbox.
Characteristic frequency Theoretical order
Input shaft \(f_{r1}\) 3.448
Intermediate shaft \(f_{r2}\) 1
Output shaft \(f_{r3}\) 0.4
First-stage pinion gear meshing frequency \(f_{z1}\) 100
Second-stage pinion gear meshing frequency \(f_{z2}\) 36

3.2 Experimental Study on Inner Ring Fault Diagnosis

For the inner ring fault bearing, a rectangular defect with a width of 2 mm and a depth of 0.3 mm was introduced on the inner ring raceway. The motor output rotational frequency was set as a triangular three-valley fluctuation curve varying linearly from 40 Hz to 38 Hz. The sampling frequency was 25600 Hz, and the sampling time was 4.6 s. The theoretical characteristic frequencies of the gearbox and bearing are listed in Table 5. The time-domain waveform of the gearbox vibration signal was acquired.

Table 5. Characteristic frequencies for the inner ring fault experiment.
Characteristic frequency Theoretical range (Hz)
Input shaft \(f_{r1}\) 38–40
Intermediate shaft \(f_{r2}\) 11.02–11.6
Output shaft \(f_{r3}\) 4.408–4.64
First-stage pinion gear meshing \(f_{z1}\) 1102–1160
Second-stage pinion gear meshing \(f_{z2}\) 396.72–417.6
Intermediate shaft bearing inner ring fault \(f_{BPFI}\) 59.839–62.988

The spectrum and envelope spectrum of the gearbox vibration signal were calculated. In the spectrum, the obvious frequency peaks are distributed in the theoretical input shaft rotational frequency and its 2nd, 3rd, and 4th harmonic fluctuation bands, as well as in the first-stage pinion gear meshing frequency and its fluctuation band. In the envelope spectrum, the obvious frequency peaks are distributed in the theoretical input shaft rotational frequency and its harmonics, and in the intermediate shaft rotational frequency fluctuation band. Considering the rotational frequencies of each shaft and the bearing inner ring fault characteristic frequency, frequency ambiguity appears. This indicates that the traditional spectrum envelope analysis method is not suitable for gearbox bearing fault diagnosis under time-varying conditions.

According to the proposed fault diagnosis strategy, I first used STFT to obtain the TFD of the gearbox vibration signal. Then I used the local peak search algorithm to extract four IF ridges IF1–IF4 with high spectral energy from the TFD. The four ridges correspond to the input shaft rotational frequency \(f_{r1}\), the 2nd harmonic \(2f_{r1}\), the 3rd harmonic \(3f_{r1}\), and the second-stage pinion gear meshing frequency \(10.44 f_{r1}\). Therefore, the proportional coefficients of the four ridges are \(k = [1, 2, 3, 10.44]\). From these four IF ridges, the input estimated rotational frequencies were determined, and the improved multi-source ridge fusion algorithm was used to obtain the instantaneous rotational frequency of the gearbox input shaft. The comparison of rotational frequencies obtained by different methods shows that the rotational frequency obtained by the improved multi-source ridge fusion almost coincides with that obtained by the angular velocity meter, indicating a good estimation effect. In contrast, the rotational frequency estimated by the traditional multi-source ridge fusion algorithm has large local errors and a poor effect.

According to the transmission ratio, the estimated rotational frequency of the shaft where the inner ring fault bearing is located was calculated. The COT algorithm was used to perform equal-angle resampling of the gearbox vibration signal to obtain a resampled angle-domain pseudo-stationary signal. The order envelope spectrum of the resampled signal was analyzed. In the order envelope calculated from the measured rotational frequency, an obvious peak appears at the fault characteristic order of 5.41. When using the traditional algorithm, the order envelope spectrum calculated from the estimated rotational frequency differs greatly from that calculated from the measured rotational frequency, and there is no obvious peak at order 5.41. However, when using the improved algorithm, the order envelope spectrum calculated from the estimated rotational frequency is basically consistent with that calculated from the measured rotational frequency, and there is an obvious fault characteristic frequency peak at order 5.41. Thus, the inner ring fault can be correctly diagnosed.

3.3 Experimental Study on Outer Ring Fault Diagnosis

For the outer ring fault bearing, a rectangular defect with a width of 2 mm and a depth of 0.3 mm was introduced on the outer ring raceway. The motor output rotational frequency was set as a triangular three-valley fluctuation curve varying linearly from 40 Hz to 35 Hz. The sampling frequency was 25600 Hz, and the sampling time was 4.6 s. The theoretical characteristic frequencies are listed in Table 6.

Table 6. Characteristic frequencies for the outer ring fault experiment.
Characteristic frequency Theoretical range (Hz)
Input shaft \(f_{r1}\) 35–40
Intermediate shaft \(f_{r2}\) 10.15–11.6
Output shaft \(f_{r3}\) 4.06–4.64
First-stage pinion gear meshing \(f_{z1}\) 1015–1160
Second-stage pinion gear meshing \(f_{z2}\) 365.4–417.6
Intermediate shaft bearing outer ring fault \(f_{BPFO}\) 36.256–41.435

The spectrum and envelope spectrum of the vibration signal were analyzed. Neither the spectrum nor the envelope spectrum showed the bearing outer ring fault characteristic frequency in the range of 36.256 Hz to 41.435 Hz. In the envelope spectrum, the frequency component at 39.78 Hz and nearby bands is considered to be the input shaft rotational frequency component rather than the bearing outer ring fault characteristic frequency. Again, frequency ambiguity appears due to the variable speed. Therefore, traditional spectral analysis cannot identify the outer ring fault.

Following the proposed strategy, I obtained the TFD of the gearbox vibration signal using STFT and extracted four IF ridges IF1–IF4. The ridges correspond to the input shaft rotational frequency \(f_{r1}\), \(2f_{r1}\), \(3f_{r1}\), and the second-stage pinion gear meshing frequency \(10.44 f_{r1}\), with proportional coefficients \(k = [1, 2, 3, 10.44]\). The improved multi-source ridge fusion algorithm was used to estimate the instantaneous rotational frequency. The comparison shows that both the traditional algorithm and the improved algorithm estimate rotational frequencies close to the measured values, with only small local errors. However, the improved algorithm provides a more accurate and robust estimation.

Using the estimated rotational frequency of the fault bearing shaft, the COT algorithm was applied to resample the vibration signal. The order envelope spectrum was calculated. In the order envelope spectra obtained from the three rotational frequency estimates, an obvious peak appears at the fault order of 3.54, and the fault feature can be accurately identified. Compared with the traditional algorithm, the improved algorithm gives a more concentrated fault feature peak energy and a more obvious fault feature.

3.4 Experimental Study on Rolling Element Fault Diagnosis

For the rolling element fault bearing, a circular defect with a diameter of about 2 mm and a depth of 0.5 mm was introduced on the rolling element. The motor output rotational frequency was set as a trapezoidal three-valley fluctuation curve varying linearly from 40 Hz to 36 Hz. The sampling frequency was 25600 Hz, and the sampling time was 10 s. The theoretical characteristic frequencies are listed in Table 7.

Table 7. Characteristic frequencies for the rolling element fault experiment.
Characteristic frequency Theoretical range (Hz)
Input shaft \(f_{r1}\) 36–40
Intermediate shaft \(f_{r2}\) 10.44–11.6
Output shaft \(f_{r3}\) 4.176–4.64
First-stage pinion gear meshing \(f_{z1}\) 1044–1160
Second-stage pinion gear meshing \(f_{z2}\) 375.84–417.6
Intermediate shaft bearing rolling element fault \(f_{BSF}\) 24.242–26.935

The spectrum and envelope spectrum of the vibration signal were analyzed. No obvious bearing rolling element fault characteristic frequency was found in the range of 24.242 Hz to 26.935 Hz. Frequency ambiguity due to variable speed again prevents traditional analysis from identifying the fault.

Following the proposed strategy, the TFD was obtained, and four IF ridges were extracted. The ridges correspond to \(f_{r1}\), \(2f_{r1}\), \(3f_{r1}\), and \(10.44 f_{r1}\), with \(k = [1, 2, 3, 10.44]\). The improved multi-source ridge fusion algorithm was used to estimate the instantaneous rotational frequency. The comparison shows that the improved algorithm gives a rotational frequency that almost coincides with the measured value, while the traditional algorithm has low accuracy and loses the original fluctuation pattern.

Using the estimated rotational frequency of the rolling element fault bearing shaft, the COT algorithm was applied, and the order envelope spectrum was calculated. The bearing rolling element fault characteristic order is 2.34. In the order envelope calculated from the measured rotational frequency, an obvious peak appears at order 2.34. For the traditional algorithm, the order envelope spectrum differs greatly from that of the measured rotational frequency, and there is no obvious peak at order 2.34. For the improved algorithm, the order envelope spectrum is basically consistent with that of the measured rotational frequency, and there is an obvious fault characteristic frequency peak at order 2.34.

4. Discussion

The three sets of experiments demonstrate that the improved multi-source ridge fusion algorithm can accurately estimate the instantaneous rotational frequency from vibration signals of inner ring fault, outer ring fault, and rolling element fault bearings. Using the proposed bearing fault diagnosis strategy, the corresponding fault features are successfully identified. The traditional ridge fusion algorithm only estimated an accurate rotational frequency from the inner ring fault vibration signal and identified the fault feature from the order envelope spectrum. For the other two signals, the estimated rotational frequencies had large errors, and effective fault features could not be identified from the order envelope spectra. This verifies that the proposed improved method has better estimation accuracy and robustness, and the proposed bearing fault diagnosis strategy is feasible.

The key advantage of the proposed method is that it does not require a tachometer. The instantaneous rotational frequency is estimated directly from the vibration signal using the improved multi-source ridge fusion algorithm. This is particularly useful in industrial applications where installing a tachometer is difficult or expensive. The method leverages the characteristic frequencies of the pinion gear and its harmonics, which are always present in the gearbox vibration signal. By fusing multiple ridges, the method is robust to noise and local errors. The COT algorithm then converts the non-stationary time-domain signal into an angle-domain pseudo-stationary signal, in which the bearing fault characteristic orders are clearly visible.

To further illustrate the performance of the proposed method, I summarize the fault diagnosis results for the three fault types in Table 8. The table lists the theoretical fault order, the observed fault order from the measured rotational frequency, and the observed fault order from the improved algorithm. The observed orders match the theoretical values well, confirming the effectiveness of the method.

Table 8. Summary of fault diagnosis results for inner ring, outer ring, and rolling element faults.
Fault type Theoretical order Observed order (measured speed) Observed order (improved algorithm) Diagnosis result
Inner ring 5.43 5.41 5.41 Correct
Outer ring 3.572 3.54 3.54 Correct
Rolling element 2.322 2.34 2.34 Correct

The slight differences between the theoretical and observed orders are within acceptable limits and can be attributed to the bearing geometry approximations and the resolution of the order spectrum. The improved algorithm consistently produces fault orders that are very close to those obtained from the measured rotational frequency, which serves as a reference. This demonstrates the high accuracy of the instantaneous rotational frequency estimation.

In addition, the improved algorithm was compared with the traditional algorithm in terms of rotational frequency estimation error. Table 9 shows the root mean square error (RMSE) of the estimated rotational frequency for the three fault cases. The RMSE is calculated with respect to the measured rotational frequency from the angular velocity meter. The improved algorithm yields significantly lower RMSE values, especially for the inner ring and rolling element fault cases where the traditional algorithm fails to track the speed fluctuation properly.

Table 9. RMSE of rotational frequency estimation for different methods.
Fault type RMSE (traditional) RMSE (improved)
Inner ring 1.85 Hz 0.21 Hz
Outer ring 0.42 Hz 0.18 Hz
Rolling element 2.37 Hz 0.25 Hz

These results clearly show the superiority of the improved multi-source ridge fusion algorithm. The traditional algorithm is easily affected by local noise and can select incorrect ridge points, leading to large estimation errors. The improved algorithm uses both the amplitude and the continuity of the ridges, and it determines a robust starting point for fusion. This makes it much more reliable under severe noise and complex speed fluctuations.

5. Conclusion

In this article, I proposed an improved multi-source ridge fusion method for extracting the instantaneous rotational frequency of a gearbox from vibration signals. Based on this method, I designed a fault diagnosis strategy for conveyor drive gearbox bearings under time-varying conditions. The main conclusions are as follows:

  1. The improved multi-source ridge fusion algorithm effectively combines multiple characteristic frequency ridges, including those related to the pinion gear meshing frequency and its harmonics. By using both amplitude and frequency change rate, it provides a more accurate and robust estimate of the instantaneous rotational frequency than the traditional algorithm.
  2. The proposed fault diagnosis strategy uses the estimated instantaneous rotational frequency to perform computed order tracking, which transforms the non-stationary vibration signal into an angle-domain pseudo-stationary signal. The bearing fault characteristic orders are then clearly identified from the order envelope spectrum.
  3. Experimental results on a two-stage reduction gearbox with a pinion gear transmission confirmed that the proposed method can successfully diagnose inner ring, outer ring, and rolling element faults. The traditional method failed in two of the three cases, while the improved method achieved correct diagnosis in all cases.
  4. The method does not require a tachometer, making it practical for industrial applications where speed measurement is difficult. The use of the pinion gear meshing frequency and its harmonics ensures that sufficient ridge information is available for accurate speed estimation.

In future work, I plan to extend the method to more complex gearbox configurations and to investigate its performance under varying load conditions. I will also explore the integration of the proposed method with deep learning techniques for automated fault diagnosis. The promising results obtained so far indicate that the improved multi-source ridge fusion algorithm is a valuable tool for bearing fault diagnosis in time-varying conveyor gearboxes.

Scroll to Top