High-Precision Face Gear Measurement Model Using an Improved POS Algorithm

I have focused my recent work on the high-precision solution of the theoretical measurement model for face gear drives. A face gear is a special gear that meshes with a cylindrical involute gear, and it is widely used when the transmitting axis and the transmitted axis have a fixed intersection angle. In my study, I treat the face gear as a critical transmission element whose tooth surface must be evaluated with great accuracy. The face gear tooth surface is generated by a shaper cutter, and the resulting geometry contains a working tooth surface, a transition surface, and a root fillet region. Because the face gear tooth surface has strong curvature variation and because the transition surface can easily contaminate measurement points, I need a reliable theoretical measurement model. The face gear measurement model must be solved accurately before any pitch error or tooth surface error can be trusted. In this article, I describe how I design the theoretical measurement model for a straight face gear, how I plan the measurement grid, and how I use an improved POS algorithm to solve the model with high precision. I also compare my results with those from a third-party software package and validate the model through a face gear measurement experiment on a CNC gear measuring center. The face gear measurement process becomes more portable and more intelligent when the theoretical model is solved internally rather than imported from an external file.

Face Gear Generation and Theoretical Tooth Surface

I begin with the generation principle of the face gear. The face gear is cut by a virtual involute cylindrical gear cutter. During the generating motion, the cutter rotates about its own axis, the face gear blank rotates about the cutter axis, and the cutter also moves transversely. The axis intersection angle between the face gear and the cutter is 90 degrees for an orthogonal face gear. The cutter usually has one to three more teeth than the mating pinion. The face gear tooth surface is the envelope of the cutter tooth profiles. I use the involute tooth profile of the cutter as the starting point. For the left and right flanks, I write the tool profile in the cutter coordinate system as a parametric involute curve. Let the base radius of the shaper cutter be $$r_{bs}$$, let the involute roll angle be $$\theta_s$$, and let the initial angle on the base circle be $$\theta_{os}$$. The position vector of the cutter tooth profile can be expressed as

$$
\mathbf{r}_s^{I,II} =
\begin{bmatrix}
r_{bs}\left(\cos(\theta_{os}+\theta_s) + \theta_s \sin(\theta_{os}+\theta_s)\right) \\
\pm r_{bs}\left(\sin(\theta_{os}+\theta_s) – \theta_s \cos(\theta_{os}+\theta_s)\right) \\
u_s \\
1
\end{bmatrix}
$$

where the superscripts I and II denote the left and right flanks, and where $$u_s$$ is the parameter along the cutter axis. The corresponding unit normal vector of the cutter tooth profile is

$$
\mathbf{n}_s^{I,II} =
\pm
\begin{bmatrix}
\cos(\theta_{os}+\theta_s) \\
\sin(\theta_{os}+\theta_s) \\
0
\end{bmatrix}
$$

I then transform the cutter profile into the face gear coordinate system. Let $$\phi_s$$ be the generating motion parameter. The transformation from the cutter coordinate system to the face gear coordinate system is represented by the matrix $$\mathbf{M}_{2s}(\phi_s)$$. The face gear tooth surface is therefore

$$
\mathbf{r}_2^{I,II}(u_s,\theta_s,\phi_s) =
\mathbf{M}_{2s}(\phi_s)\mathbf{r}_s^{I,II}(u_s,\theta_s)
$$

with the meshing equation

$$
f(u_s,\theta_s,\phi_s) =
\mathbf{n}_s^{I,II} \cdot \mathbf{v}_s^{(s2),I,II} = 0
$$

where $$\mathbf{v}_s^{(s2),I,II}$$ is the relative velocity between the face gear and the cutter during the generating motion. The normal vector of the generated face gear tooth surface is obtained by applying the 3 by 3 submatrix $$\mathbf{L}_{2s}(\phi_s)$$ of $$\mathbf{M}_{2s}(\phi_s)$$ to the cutter normal:

$$
\mathbf{n}_2^{I,II}(u_s,\theta_s,\phi_s) =
\mathbf{L}_{2s}(\phi_s)\mathbf{n}_s^{I,II}(u_s,\theta_s)
$$

The transition surface of the face gear is formed by the sweeping motion of the cutter tip. The intersection between the working tooth surface and the transition surface is the transition curve. This curve is the common tangent of the two surfaces and is also the boundary between the working surface and the transition surface. I determine it from the contact line on the working surface and the tip cylinder generatrix of the shaper cutter. When the involute roll angle reaches a critical value $$\theta_s = \theta_s^*$$, the axial parameter along the cutter becomes

$$
u_s(\phi_s) =
\frac{r_{bs}(1 – m_{2s}\cos\gamma_m)}
{m_{2s}\sin\gamma_m \cos(\phi_s+\theta_{os}+\theta_s^*)}
$$

where $$m_{2s}$$ and $$\gamma_m$$ are geometric parameters of the generating motion. The transition curve in the face gear coordinate system $$S_2$$ is then written as

$$
\mathbf{R}_g(\phi_s) =
\mathbf{r}_2\left[u_s(\phi_s),\phi_s\right] =
\mathbf{M}_{g2}\mathbf{r}_s\left[u_s(\phi_s)\right]
$$

This transition curve is essential for my measurement model because measurement points must not fall on the transition surface. If a measurement point lies on the transition surface, the measured deviation will not represent the working tooth surface and the face gear evaluation will be incorrect. Therefore, I use the transition curve to adjust the tooth-height boundaries of the measurement grid, especially near the small end and the root of the face gear.

Theoretical Measurement Model and Measurement Grid Planning

After I obtain the theoretical face gear tooth surface, I still need to convert it into a measurement model that matches the CNC gear measuring center. The design coordinate system of the face gear is not identical to the measurement coordinate system. In my measurement setup, the face gear is mounted on a dedicated support on the rotary table of the measuring center. I align the face gear bore with the rotary center using a dial indicator, and I adjust the support so that the face gear axis is horizontal. The probe first approaches the upper end face of the face gear to establish the axial datum. I mark that position as the Z-axis origin. The design coordinate system and the measurement coordinate system share the same origin after alignment, but the theoretical measurement model still requires a coordinate transformation because the face gear model generated from the cutter coordinate system is not directly expressed in the measurement coordinate system. I apply the transformation

$$
\mathbf{r}_m = \mathbf{M}_{2m}\mathbf{r}_2
$$

where $$\mathbf{M}_{2m}$$ is the transformation matrix from the design coordinate system to the measurement coordinate system. For the face gear setup I use, this matrix takes the form

$$
\mathbf{M}_{2m} =
\begin{bmatrix}
1 & 0 & 0 & 0 \\
0 & 1 & 0 & 0 \\
0 & 0 & 1 & r_{ds} \\
0 & 0 & 0 & 1
\end{bmatrix}
$$

where $$r_{ds}$$ is the tip radius of the shaper cutter. This transformation shifts the theoretical face gear tooth surface along the Z-axis so that the measurement model and the actual face gear mounting position are consistent.

I then plan the measurement grid on the working tooth surface. Because a face gear lacks a dedicated measurement standard, I borrow the general practice used for bevel gears. I select a fixed region on the tooth surface that reflects the tooth surface error. I avoid the tooth tip chamfer and the root fillet by shrinking the measurement region inward. In the tooth-height direction, I shrink 5 percent of the working tooth height from the tip and from the root. In the face-width direction, I shrink 10 percent of the face width from the inner end and from the outer end. These shrinkages ensure that the probe radius does not touch the fillet and that the measurement points remain on the working surface. I divide the resulting region into 9 points along the face width and 5 points along the tooth height. This produces a 9 by 5 measurement grid with 45 measurement points. The grid planning is summarized in Table 1.

Direction Shrinkage at Start Shrinkage at End Number of Points Purpose
Face width 10 percent from inner end 10 percent from outer end 9 Avoid inner and outer edges
Tooth height 5 percent from tooth tip 5 percent from tooth root 5 Avoid tip chamfer and root fillet
Total grid 45 measurement points 9 by 5 array 45 Represent working face gear tooth surface

The grid is not necessarily uniform in the tooth-height direction when the transition surface is present. Near the small end of the face gear, the transition surface may cut into the planned region, so I adjust the iterative step size along the tooth height. Near the large end, the transition surface usually does not affect the working region, and I keep the step size constant. In this way, every planned measurement point lies on the working tooth surface of the face gear. The resulting theoretical measurement model is a set of coordinates and normal vectors that the CNC gear measuring center can use to guide the probe.

Solving the Face Gear Measurement Model with an Improved POS Algorithm

The theoretical measurement model of the face gear is defined by nonlinear equations. Solving these equations directly can be difficult because the face gear tooth surface is a complex enveloping surface and because the transition curve introduces additional constraints. I convert the nonlinear equation solving problem into a least-squares problem and solve it with an improved POS algorithm. The POS algorithm treats candidate solutions as particles in a search space. Each particle has a position and a velocity. The particles update their positions and velocities according to their own best experience and the best experience of the swarm. I use the following objective function for the face gear measurement model:

$$
M(\theta_s,\phi_s) =
\frac{1}{
\sqrt{
\left(
\sqrt{x_2^2 + y_2^2} – X
\right)^2
+
\left(
z_2 – Z
\right)^2
}
}
$$

where $$x_2$$, $$y_2$$, and $$z_2$$ are the coordinates of a point on the theoretical face gear measurement model, and $$X$$ and $$Z$$ are the planned grid components in the radial and axial directions. The objective function reaches its maximum when the computed point coincides with the planned grid point. In practice, I minimize the denominator or maximize this function. The problem is two-dimensional in the parameters $$\theta_s$$ and $$\phi_s$$. I let the swarm contain $$m$$ particles. At iteration $$k$$, the velocity and position of particle $$j$$ are updated by

$$
V_j^{k+1} =
w V_j^k +
c_1 r_1 \left(P_j^k – X_j^k\right) +
c_2 r_2 \left(P_g^k – X_j^k\right)
$$

$$
X_j^{k+1} = X_j^k + V_j^{k+1}
$$

where $$P_j^k$$ is the individual best position of particle $$j$$, $$P_g^k$$ is the global best position of the swarm, $$r_1$$ and $$r_2$$ are random numbers between 0 and 1, and $$c_1$$ and $$c_2$$ are learning factors. I use a dynamic inertia weight to balance global exploration and local exploitation. The inertia weight is

$$
w = w_0 – 0.5 \left(\frac{i}{T_{\max}}\right)^2
$$

where $$w_0$$ is the initial inertia weight, $$i$$ is the current iteration number, and $$T_{\max}$$ is the maximum number of iterations. I set $$w_0 = 0.9$$, $$c_1 = c_2 = 1.82$$, and I use the parameter values listed in Table 2. These values were selected after preliminary trials to ensure stable convergence for the face gear measurement model.

Parameter Symbol Value Description
Swarm size $$m$$ 50 Number of particles in the swarm
Maximum iterations $$T_{\max}$$ 500 Iteration limit for convergence
Initial inertia weight $$w_0$$ 0.9 Controls initial global search
Learning factor 1 $$c_1$$ 1.82 Cognitive component
Learning factor 2 $$c_2$$ 1.82 Social component
Random numbers $$r_1, r_2$$ Uniform in [0,1] Stochastic search
Search dimension 2 $$\theta_s, \phi_s$$ Involute angle and generating parameter
Convergence tolerance $$\epsilon$$ $$1 \times 10^{-8}$$ Stopping criterion

The improved POS algorithm is implemented on the Visual C++ 6.0 platform. I integrate it directly into the face gear measurement software so that the theoretical measurement model can be solved inside the measuring system. This removes the need for an external file from a third-party software package. The solver first determines the inner and outer boundaries of the measurement region from the face gear inner and outer radii. It then computes the transition curve and obtains the tooth-height coordinate of the transition curve. It checks whether the transition curve exists in the current tooth-height region. If it does, the solver adjusts the tooth-height shrinkage and the iterative step size. Finally, it solves the theoretical measurement points on the prescribed grid. The result is a set of 45 measurement points with their coordinates and normal vectors.

To verify the accuracy of the improved POS algorithm, I compare its results with those obtained from a third-party software package. I define the single-axis error as the maximum absolute projection of the coordinate difference on each axis:

$$
\Delta X = \max \left| X_m – X_c \right|
$$

$$
\Delta Y = \max \left| Y_m – Y_c \right|
$$

$$
\Delta Z = \max \left| Z_m – Z_c \right|
$$

I define the composite error as the maximum resultant magnitude of the coordinate differences:

$$
\Delta S = \max \sqrt{
\Delta X^2 + \Delta Y^2 + \Delta Z^2
}
$$

The comparison results are shown in Table 3. The maximum error in the X-axis is 0.5 micrometers, the maximum error in the Y-axis is 0.5 micrometers, and the maximum error in the Z-axis is 0.8 micrometers. These single-axis errors do not occur at the same measurement point. The maximum composite error is only 0.9 micrometers. This demonstrates that the improved POS algorithm can solve the face gear theoretical measurement model with high precision. The small composite error confirms that the face gear measurement model is reliable for subsequent experimental validation.

Error Type Symbol Maximum Value Unit Observation
X-axis error $$\Delta X$$ 0.5 micrometer Does not coincide with other maxima
Y-axis error $$\Delta Y$$ 0.5 micrometer Does not coincide with other maxima
Z-axis error $$\Delta Z$$ 0.8 micrometer Does not coincide with other maxima
Composite error $$\Delta S$$ 0.9 micrometer Maximum resultant difference

Experimental Validation of the Face Gear Measurement Model

I validate the theoretical measurement model by measuring a face gear on a CNC gear measuring center. The basic design parameters of the face gear are listed in Table 4. The shaper cutter has 27 teeth, the face gear has 81 teeth, the module is 3.3 millimeters, the pressure angle is 25 degrees, the inner radius is 129 millimeters, and the outer radius is 149 millimeters. These parameters are entered into the face gear measurement software to solve the theoretical measurement model. The software then outputs the theoretical measurement coordinates and normal vectors. A portion of the theoretical measurement model coordinates is listed in Table 5. Each row in Table 5 corresponds to a grid point on the face gear tooth surface. The columns are the row index, the column index, the x, y, and z coordinates in millimeters, and the normal vector components $$n_x$$, $$n_y$$, and $$n_z$$. I use these points to program the measuring path on the CNC gear measuring center.

Parameter Symbol Value Unit
Shaper cutter teeth $$N_s$$ 27 teeth
Face gear teeth $$N_2$$ 81 teeth
Module $$m$$ 3.3 millimeter
Pressure angle $$\alpha_n$$ 25 degree
Inner radius $$R_1$$ 129 millimeter
Outer radius $$R_2$$ 149 millimeter
Row Column $$x$$ (mm) $$y$$ (mm) $$z$$ (mm) $$n_x$$ $$n_y$$ $$n_z$$
1 1 -3.734093 -130.946770 -6.27 0.922278 -0.922278 -0.922278
1 2 -3.920857 -132.942194 -6.27 0.908879 -0.908879 -0.908879
1 3 -4.072966 -134.938545 -6.27 0.895791 -0.895791 -0.895791
1 4 -4.197832 -136.935672 -6.27 0.883031 -0.883031 -0.883031
1 5 -4.300219 -138.933467 -6.27 0.870597 -0.870597 -0.870597
1 6 -4.383474 -140.931846 -6.27 0.858483 -0.858483 -0.858483
1 7 -4.450087 -142.930741 -6.27 0.846682 -0.846682 -0.846682
1 8 -4.501991 -144.930094 -6.27 0.835184 -0.835184 -0.835184
1 9 -4.540731 -146.929853 -6.27 0.823979 -0.823979 -0.823979
2 1 -3.129342 -130.962618 -4.785 0.923382 -0.923382 -0.923382
2 2 -3.250618 -132.960270 -4.785 0.909829 -0.909829 -0.909829
2 3 -3.343649 -134.958586 -4.785 0.896621 -0.896621 -0.896621
2 4 -3.413802 -136.957460 -4.785 0.883759 -0.883759 -0.883759
2 5 -3.464716 -138.956813 -4.785 0.871237 -0.871237 -0.871237
2 6 -3.499034 -140.956578 -4.785 0.859044 -0.859044 -0.859044
2 7 -3.518771 -142.956701 -4.785 0.847170 -0.847170 -0.847170
2 8 -3.525515 -144.957134 -4.785 0.835606 -0.835606 -0.835606

I mount the face gear horizontally on a dedicated support on the rotary table of the CNC gear measuring center. I adjust the support until the face gear axis coincides with the rotary center. I then input the face gear parameters into the solver, calibrate the probe, and start the automatic measurement of pitch and tooth surface errors. The measurement setup is shown in the following figure, which I include to illustrate the practical arrangement of the face gear on the measuring center.

I define the pitch error for the face gear according to the general practice used for bevel gears. The pitch error is the difference between the actual arc length and the theoretical arc length for the midpoints of two adjacent tooth flanks on the same side. The midpoint of the measurement grid is taken as the point at row 3 and column 5. The cumulative pitch error is the difference between the actual arc length and the theoretical arc length for any two tooth flanks on the same side. I define the tooth surface error as the projection of the actual tooth surface along the theoretical normal direction at each grid point, using the midpoint of the measurement grid as the reference point. The measurement results are summarized in Table 6 and Table 7.

Table 6 shows the pitch error and cumulative pitch error. The pitch errors on the left and right flanks of the face gear are both less than 20 micrometers. Because the face gear itself has manufacturing errors, the cumulative pitch errors on the left and right flanks differ from each other. The maximum cumulative pitch error does not exceed 40 micrometers, and the cumulative pitch error distribution is approximately sinusoidal. This behavior is consistent with the expected face gear manufacturing deviation pattern. The face gear has many teeth, so I select three evenly distributed teeth, namely tooth 1, tooth 27, and tooth 53, for tooth surface error measurement. This reduces the measurement time while preserving a representative evaluation of the face gear tooth surface.

Measurement Item Left Flank Right Flank Unit Observation
Maximum pitch error Less than 20 Less than 20 micrometer Both sides acceptable
Maximum cumulative pitch error Less than 40 Less than 40 micrometer Approximately sinusoidal
Selected teeth for surface error 1, 27, 53 1, 27, 53 Tooth number Evenly distributed

Table 7 shows the average tooth surface error for the three selected teeth. The face gear tooth surface error increases gradually from the midpoint of the measurement grid toward the face width and tooth height boundaries. On the left flank, the maximum error at the small end is 8.2 micrometers, and the maximum error at the large end is -22.2 micrometers. On the right flank, the maximum error at the small end is 9.7 micrometers, and the maximum error at the large end is -14.0 micrometers. The negative sign indicates that the actual tooth surface lies inside the theoretical tooth surface along the normal direction, while the positive sign indicates that the actual tooth surface lies outside the theoretical tooth surface. These results confirm that the theoretical measurement model and the improved POS solver are effective for high-precision face gear measurement.

Location Left Flank Error (micrometer) Right Flank Error (micrometer) Trend
Small end 8.2 9.7 Positive deviation
Mid region Reference Reference Zero reference point
Large end -22.2 -14.0 Negative deviation
Tooth height variation Increases toward tip and root Increases toward tip and root Curvature effect

Discussion of Face Gear Measurement Accuracy and Portability

The experimental results show that the face gear measurement model solved by the improved POS algorithm is accurate enough for practical face gear inspection. The maximum composite error of 0.9 micrometers compared with third-party software indicates that the internal solver does not introduce significant numerical error. The pitch error and cumulative pitch error measurements further demonstrate that the face gear measurement model can reproduce the actual face gear geometry. The tooth surface error distribution reveals the characteristic deviation pattern of the face gear, with larger deviations near the large end and smaller deviations near the small end. This pattern is useful for diagnosing manufacturing errors and for improving the face gear cutting process.

From a software perspective, the improved POS algorithm improves the portability of the face gear measurement system. In many conventional systems, the theoretical measurement model is computed by an external software package and then imported into the measuring machine. This workflow increases the workload of the operator, reduces real-time capability, and limits the intelligence of the face gear measurement process. By embedding the solver into the measurement software, I eliminate the external dependency. The face gear measurement software can now generate the theoretical measurement model, solve the grid points, and perform the measurement in a single environment. This is especially important for face gear measurement because the face gear tooth surface is complex and the transition surface must be handled carefully. The internal solver can respond to changes in face gear parameters without requiring a new external computation.

I also note that the grid planning is critical for face gear measurement accuracy. If the measurement grid extends into the transition surface, the measured tooth surface error will be contaminated by the root fillet and will not represent the working face gear tooth surface. My grid planning method avoids this problem by shrinking the measurement region and by adjusting the tooth-height step size near the small end. The 9 by 5 grid is a practical compromise between measurement time and spatial resolution. A finer grid could provide more detail, but it would increase the measurement time and the probability of probe interference. For the face gear studied here, the 9 by 5 grid captures the main features of the tooth surface error distribution. The grid planning parameters are summarized in Table 8 for clarity.

Grid Parameter Value Reason
Face width points 9 Capture face width variation
Tooth height points 5 Capture tooth height variation
Total points 45 Balance accuracy and time
Inner end shrinkage 10 percent Avoid inner edge and transition
Outer end shrinkage 10 percent Avoid outer edge
Tip shrinkage 5 percent Avoid tip chamfer
Root shrinkage 5 percent Avoid root fillet

The improved POS algorithm also has advantages over gradient-based solvers for the face gear measurement model. The objective function of the face gear model is nonlinear and may have multiple local minima because of the enveloping geometry and the transition curve. The POS algorithm is a population-based stochastic search method, and it does not require derivative information. It explores the search space broadly in the early iterations and then converges to the global optimum. The dynamic inertia weight helps the swarm avoid premature convergence. In my implementation, the algorithm consistently converges to the same solution within the specified tolerance. This robustness is important for a measurement software system that must operate reliably in an industrial environment.

I further evaluated the sensitivity of the improved POS algorithm to the swarm size and the maximum number of iterations. The results are summarized in Table 9. When the swarm size is too small, the algorithm may converge slowly or become trapped in a local optimum. When the swarm size is large, the computation time increases without a significant improvement in accuracy. I found that a swarm size of 50 and a maximum of 500 iterations provide a good balance. The convergence tolerance of $$1 \times 10^{-8}$$ ensures that the solved measurement points are accurate to well below one micrometer. These settings are used for all face gear measurement models in my study.

Swarm Size Maximum Iterations Convergence Behavior Accuracy Recommended Use
20 500 Slow and sometimes local Moderate Quick preliminary study
30 500 Stable but slower Good General purpose
50 500 Stable and fast High Recommended for face gear
80 500 Very stable High Higher computation cost
50 200 May not fully converge Moderate Not recommended
50 1000 Fully converged High Unnecessary for this model

Another important aspect of the face gear measurement model is the normal vector computation. The normal vector determines the probe compensation direction and the projection direction for tooth surface error. If the normal vector is inaccurate, the measured tooth surface error will be biased. In my model, I compute the normal vector by transforming the cutter normal through the 3 by 3 submatrix of the coordinate transformation. The normal vector is then normalized before it is used in the measurement software. The normal vectors listed in Table 5 show that the components vary smoothly across the face gear tooth surface. This smooth variation confirms that the theoretical measurement model is geometrically consistent and that the face gear tooth surface is properly represented.

The measurement experiment also validates the practical use of the face gear measurement model. The CNC gear measuring center has a high-precision rotary table and a probe system that can follow the planned measurement path. The face gear is mounted on a dedicated support, and the alignment procedure ensures that the measurement coordinate system coincides with the design coordinate system. The pitch error and tooth surface error results are obtained automatically from the measurement software. The face gear measurement software displays the error distribution and provides a quantitative evaluation of the face gear accuracy. This demonstrates that the theoretical measurement model is not only numerically accurate but also operationally feasible.

Conclusion

I have designed a high-precision theoretical measurement model for a straight face gear and solved it with an improved POS algorithm. The face gear measurement model is based on the generating principle of the face gear and the measurement principle of the CNC gear measuring center. I planned the measurement grid on the working tooth surface and avoided the transition surface by shrinking the measurement region and by adjusting the tooth-height step size. I converted the nonlinear equation solving problem into a least-squares problem and solved it with a population-based POS algorithm. The improved POS algorithm uses a dynamic inertia weight and a two-dimensional search over the involute roll angle and the generating parameter. The solved theoretical measurement points and normal vectors are accurate to within 0.9 micrometers when compared with a third-party software package. The experimental validation on a CNC gear measuring center produced pitch errors less than 20 micrometers, cumulative pitch errors less than 40 micrometers, and tooth surface errors with a clear distribution trend. The left flank small end error is 8.2 micrometers, the left flank large end error is -22.2 micrometers, the right flank small end error is 9.7 micrometers, and the right flank large end error is -14.0 micrometers. These results confirm that the face gear measurement model is effective and that the improved POS algorithm is suitable for high-precision face gear measurement. The method also improves the portability of the face gear measurement software system because the theoretical model is solved internally rather than imported from an external package. I believe that this approach can be extended to other types of face gears and can support the development of more intelligent face gear measurement software in the future.

Scroll to Top