No-load Power Method for Worm Gear Elevator Balance Factor Measurement

The balance factor of a traction elevator is a crucial performance parameter, designed to balance the rated load with the counterweight, thereby effectively reducing the load on the drive motor. According to TSG T7001-2009, the balance factor for traction elevators should be between 0.40 and 0.50, or comply with the design value of the manufacturer. Directly related to safe operation, an excessively small balance factor may cause the car to hit the pit when fully loaded downward, while an excessively large factor may lead to an overspeed upward when empty. Traditional measurement methods, such as the current-load curve method (hereafter referred to as the current method), involve loading the car with 30%, 40%, 45%, 50%, and 60% of the rated load and running the elevator fully up and down to find the intersection of the up and down current curves. Although this method is simple and reliable, it is time-consuming and labor-intensive. In this paper, I introduce a no-load power method (hereafter referred to as the power method) for measuring the balance factor, and demonstrate its applicability to worm gear drive elevators through theoretical and practical analysis.

Theoretical Basis of the No-load Power Method

In physics, power is defined as the rate at which work is done per unit time. For an elevator, the motor power during no-load operation can be derived from the force balance:

$$
N = \frac{(W – P) v g_n}{\eta} = \frac{q Q v g_n}{\eta}
$$

where \(W\) is the mass of the counterweight (kg), \(P\) is the mass of the empty car and supported components (kg), \(v\) is the car speed (m/s), \(g_n\) is the gravitational acceleration (9.81 m/s²), \(\eta\) is the transmission efficiency, \(q\) is the balance factor under no-load condition, and \(Q\) is the rated load (kg). When the elevator is empty, the counterweight side is always heavier than the car side. During empty downward travel, the motor operates in motoring mode; during empty upward travel, the motor operates in regenerative braking mode. Therefore, the motor power when the car and counterweight are at the same level can be expressed as:

$$
N_x = q Q g_n v_x + q Q g_n v_x (1 – \eta_x)
$$

$$
N_s = q Q g_n v_s – q Q g_n v_s (1 – \eta_s)
$$

Here, \(N_x\) and \(v_x\) are the power and speed during empty downward travel, while \(N_s\) and \(v_s\) correspond to empty upward travel. \(\eta_x\) and \(\eta_s\) are the transmission efficiencies for downward and upward travel, respectively. Adding the two equations yields:

$$
\frac{N_x}{v_x} + \frac{N_s}{v_s} = 2 q Q g_n + q Q g_n (\eta_s – \eta_x)
$$

Thus, the balance factor can be derived as:

$$
q = \frac{ N_x v_s + N_s v_x }{ (2 + \eta_s – \eta_x) Q g_n v_x v_s }
$$

If the transmission efficiencies are identical for empty upward and downward travel (\(\eta_x = \eta_s\)), the equation simplifies to:

$$
q = \frac{ N_x v_s + N_s v_x }{ 2 Q g_n v_x v_s }
$$

This simplified equation forms the theoretical basis of the no-load power method. The key condition is that the transmission efficiency must be the same in both directions.

Applicability to Permanent Magnet Synchronous Gearless and Worm Gear Elevators

Permanent Magnet Synchronous Gearless Elevators

Permanent magnet synchronous gearless traction machines consist of a permanent magnet synchronous motor, a traction sheave, and a braking system. The rotor carries high-performance rare-earth permanent magnets that produce a constant magnetic field, while the stator contains coils that generate a rotating magnetic field when supplied with three-phase alternating current. The interaction of these fields rotates the motor. The key advantage is the absence of intermediate transmission mechanisms—the sheave is directly driven through shafts and bearings, achieving a transmission efficiency of about 95%. Because there is no gear train, the efficiency for forward and reverse rotation is inherently identical, i.e., \(\eta_x = \eta_s\). Therefore, the no-load power method is fully applicable to permanent magnet synchronous gearless elevators.

Worm Gear Drive Elevators

Worm gear drives are widely used in mechanical transmissions due to their high reduction ratios, smooth operation, compactness, and self-locking characteristics. They were especially common in early elevator traction machines. However, compared to gearless permanent magnet synchronous machines, worm gear drives suffer from lower transmission efficiency, typically around 70%.

The overall transmission efficiency of a worm gear system is given by:

$$
\eta = \eta_1 \eta_2 \eta_3
$$

where \(\eta_1\) is the meshing efficiency of the worm and worm wheel, \(\eta_2\) is the bearing efficiency, and \(\eta_3\) is the oil churning efficiency. The bearing and churning efficiencies are generally the same regardless of the direction of rotation. The meshing efficiency, however, depends primarily on the coefficient of friction between the worm and worm wheel tooth surfaces during relative sliding. A lower friction coefficient leads to higher efficiency. For an empty worm gear elevator, the counterweight side is always heavier than the car side, so the torque on the traction sheave remains constant in magnitude and direction (except during acceleration and deceleration). Due to the self-locking property of worm gear drives, the worm always drives the worm wheel, and the direction of forces on the tooth surfaces is unchanged whether the elevator is moving upward or downward. Consequently, the tooth surfaces that engage and the sliding friction coefficient are the same in both directions. Therefore, the meshing efficiency \(\eta_1\) is identical for empty upward and downward travel, and so is the total efficiency \(\eta_x = \eta_s\). This theoretical reasoning confirms that the no-load power method is also applicable to worm gear drive elevators.

Case Study: Application of the No-load Power Method to Worm Gear Elevators

To validate the theoretical analysis, I conducted field tests on four identical worm gear drive elevators (labeled A, B, C, and D) installed in a residential community. These elevators were manufactured in July 2002, with specifications shown in Table 1.

Parameter Value
Manufacturing Date July 2002
Equipment Type Traction-driven passenger elevator
Drive Type Worm gear drive
Rated Load 1000 kg
Rated Speed 1.75 m/s
Number of Floors/Stops 22 floors/22 stops

Table 1: Parameters of the four worm gear elevators used in the study.

First, I measured the balance factors using the traditional current method. The results are shown in Table 2.

Elevator Balance Factor (%) Load (%) Actual Load (kg) Upward Current (A) Downward Current (A)
A 44.2 30 300 13.2 15.8
40 400 13.4 14.2
45 460 13.7 13.6
50 500 14.5 13.4
60 600 16.2 13.1
B 43.6 30 300 9.4 13.9
40 400 10.4 11.6
45 460 11.4 10.7
50 500 12.3 10.2
60 600 14.3 9.5
C 43.1 30 300 13.0 15.7
40 400 13.5 14.3
45 460 14.2 13.5
50 500 15.1 13.3
60 600 16.6 13.1
D 42.9 30 300 9.5 14.5
40 400 10.7 11.9
45 460 12.1 10.5
50 500 13.1 10.1
60 600 15.3 9.4

Table 2: Balance factors obtained by the current method for the four worm gear elevators.

Next, I applied the no-load power method using a specialized balance factor tester. The results are shown in Table 3.

Elevator Balance Factor (%) Rated Load (kg) Upward Speed (m/s) Downward Speed (m/s) Personnel Weight (kg)
A 45.0 1000 1.64 1.63 60
B 44.5 1000 1.47 1.55 60
C 43.8 1000 1.61 1.60 60
D 43.1 1000 1.64 1.61 60

Table 3: Balance factors obtained by the no-load power method for the four worm gear elevators.

The transmission efficiency of a worm gear is significantly influenced by the friction coefficient, which is directly related to tooth surface wear. Heavier wear implies lower efficiency. I visually inspected the worm wheel tooth surfaces of the four elevators, as shown in Figure 1. I classified the wear into three grades: Grade I (least wear), Grade II (moderate wear), and Grade III (most severe wear). The comparative analysis is summarized in Table 4.

Table 4: Comparison of balance factors from current method and power method for the four worm gear elevators.

Elevator Balance Factor (Current Method) (%) Balance Factor (Power Method) (%) Worm Wheel Wear Grade Relative Deviation (%)
A 44.2 45.0 I 1.8
B 43.6 44.5 I 2.1
C 43.1 43.8 III 1.6
D 42.9 43.1 II 0.5

As evident from Table 4, the balance factors measured by the current method and the power method show relatively small deviations, ranging from 0.5% to 2.1%. Importantly, the variations in worm wheel wear grades and consequent differences in transmission efficiency did not significantly affect the power method results. This indicates that the no-load power method is well-suited for worm gear drive elevators, and experimentally confirms that the transmission efficiency during empty upward and downward travel is indeed equal (\(\eta_x = \eta_s\)).

Significance of the No-load Power Method for Aging Elevator Inspection

In many countries, including China, elevators have no mandatory retirement age. Many elevators that have exceeded their design life of 15 years are still in service, often with significant safety hazards: excessive wear of suspension ropes, worn traction sheave grooves, insufficient braking torque, and abnormal balance factors. Many spare parts for these aging elevators are no longer produced, making maintenance difficult. Consequently, these ageing machines operate under “sick” conditions, threatening passenger safety. Therefore, periodic inspection of balance factors is especially critical. When traction sheave groove wear is suspected, the balance factor should be checked first before conducting traction capability tests.

Nowadays, some manufacturers integrate the no-load power method module directly into the control cabinet of new elevators, enabling real-time monitoring of the balance factor. However, most aging elevators, especially those with worm gear drives, still require on-site inspection. The traditional current method necessitates repeated loading of heavy weights into the car, typically taking about one hour per elevator under favorable conditions. In contrast, the no-load power method takes approximately ten minutes, drastically reducing time cost. Moreover, the power method requires less manpower—often a single technician can complete the measurement, lowering labor costs significantly.

Conclusion

The no-load power method has gradually been adopted in the elevator industry nationwide. The State Administration for Market Regulation has been actively promoting innovation in special equipment inspection techniques. As inspection professionals, we should embrace this progress and contribute to the development of the field. The theoretical and experimental evidence presented in this paper confirms that the no-load power method is applicable to worm gear drive elevators, as the transmission efficiency is proven to be equal in both directions of empty travel. The method offers a faster, more efficient, and less labor-intensive alternative to the traditional current method, especially beneficial for the inspection of aging worm gear elevators.

Scroll to Top