Rack and Pinion Gear Effects on Coke Pusher Vibration

I have investigated the vibration behavior of a large coke pushing device used in a 6.25 m stamp-charging coke oven. The machine is part of a complete set of coke oven equipment, and its main task is to open and close the oven door on the machine side, level the coal after charging, and push the mature red coke out of the carbonization chamber so that it falls through a guide chute into the quenching car. During field operation, I observed strong vibration in the coke pushing device. This vibration can loosen and displace refractory bricks at the oven head and bottom, cause leakage between the carbonization chamber and the combustion chamber, affect normal operation, and even lead to coal cake collapse, which poses a safety threat to workers. Among the many possible causes, the rack and pinion gear transmission system is a central excitation source because it drives the pushing rod forward and backward. Therefore, I focused on how the rack and pinion gear transmission system influences the vibration characteristics of the coke pushing device.

The coke pushing device consists mainly of a pushing rod, a pushing head, a sliding shoe, and a rack and pinion gear drive system. The pushing rod is the core component. In the 6.25 m stamp-charging coke oven equipment that I studied, the pushing rod is approximately 27 m long, 0.34 m wide, and 1.05 m high. The front end of the pushing rod is fixed to the pushing head. During pushing, the pushing head contacts the coke directly and pushes it out of the carbonization chamber. A sliding shoe is installed near the lower end face of the pushing rod close to the pushing head. This sliding shoe supports the part of the pushing rod that enters the carbonization chamber. The lower surface of the sliding shoe contacts the refractory bricks in the carbonization chamber, so its motion involves sliding friction. Several support rollers are also arranged under the pushing rod. These rollers are mounted on the working foundation, and rolling friction occurs between the pushing rod and the rollers. On the upper end face of the pushing rod, a rack and pinion gear transmission mechanism is installed. During operation, an electric motor drives the rack and pinion gear after speed reduction, thus pushing the rod forward and backward. The schematic structure of the coke pushing device is shown in the following figure.

To understand why the rack and pinion gear transmission system causes vibration, I combined finite element simulation with experimental analysis. First, I performed modal analysis of the coke pushing device using finite element simulation. I extracted low-order mode shapes for both free modality and constrained modality. Second, I used field-measured vibration data for time-frequency analysis. I calculated the rotation frequency of the gear and the meshing frequency of the rack and pinion gear in the transmission system. Finally, I compared the modal analysis results with the characteristic frequencies of the rack and pinion gear transmission system. The results show that both the meshing transmission of the rack and pinion gear and the rotation of the gear cause obvious vibration of the coke pushing device. I also found that changing the number of gear teeth and adjusting the operating frequency of the motor can effectively reduce the possibility of vibration.

Modal analysis is the foundation of my investigation. Modal analysis identifies the inherent vibration characteristics of a mechanical structure. Every mode has a specific natural frequency, damping ratio, and mode shape. These vibration modes reflect the overall inherent properties of the mechanical structure. By performing modal analysis, I can obtain the characteristics of each mode within a frequency range that is likely to be excited. Then I can predict the actual vibration response of the structure under various internal and external excitation sources in that frequency band. For a linear system with n degrees of freedom, the equation of motion can be written as

$$ M\ddot{Y} + C\dot{Y} + KY = F(t) $$

where \(M\), \(K\), and \(C\) are the mass matrix, stiffness matrix, and damping matrix of the structure, respectively. \(Y\) is the displacement vector, and its first and second derivatives represent the velocity vector and acceleration vector of the structure. \(F(t)\) is the dynamic load vector acting on the structure, and \(t\) is time.

If I set \(F(t)=0\), I obtain the free vibration equation of the structure from the equation of motion. In practical engineering applications, damping has a weak effect on the natural frequencies and mode shapes of the structure, so I neglect it. Therefore, I remove the damping matrix from the equation and obtain the free vibration equation as

$$ M\ddot{Y} + KY = 0 $$

Generally, free vibration can be regarded as the superposition of several sinusoidal vibrations with different amplitudes and phases. Therefore, the solution of this vibration equation can be expressed as

$$ Y = A\sin(\omega t + \phi) $$

where \(A\) is the displacement amplitude vector, \(\omega\) is the natural frequency, and \(\phi\) is the phase angle. Substituting this solution into the free vibration equation gives

$$ (K – \omega^2 M)A = 0 $$

To obtain a non-zero solution ofthis equation, the following condition must be satisfied:

$$ |K – \omega^2 M| = 0 $$

Solving this equation yields \(n\) free vibration frequencies \(\omega_1, \omega_2, \ldots, \omega_n\), which are the \(n\) natural frequencies of the system. Substituting these natural frequencies back into the displacement expression gives the corresponding \(n\) eigenvectors \(A\), which are the \(n\) mode shapes of the system.

I used free modal analysis to study the vibration characteristics of the coke pushing device without external forces and constraints. I based design improvements on the free modal results. In actual field work, I aimed to avoid the situation where the excitation frequency approaches the natural frequency of the structure, thereby reducing vibration, improving reliability and stability, and extending service life. Because the coke pushing device that I studied is more than 20 m long and has a mass of about 40 t, and because the carbonization chamber is a high-temperature closed space with a dangerous and complex working environment, it is very difficult to obtain the natural frequencies of the device experimentally under existing technical conditions. Therefore, I used ANSYS finite element analysis software to analyze the free modes of the coke pushing device.

In free modal analysis, the first few natural frequencies of the coke pushing device are close to zero, and these can be regarded as rigid body modes without reference value. Starting from the fourth mode, the values are effective for free modal analysis. Through field test observations, I found that the coke pushing device has obvious low-frequency vibration. Therefore, I extracted modes 4 through 9 of the coke pushing device.

The free modal analysis results for modes 4 to 9 are summarized in Table 1.

Table 1. Free modal analysis results for modes 4 to 9 of the coke pushing device
Mode order Frequency (Hz) Maximum displacement (mm)
4 0.1697 7.2685
5 0.5116 7.3743
6 2.3852 8.4133
7 5.3507 8.3197
8 5.4494 16.226
9 7.1873 10.294

From Table 1, I can see that as the mode order increases, the natural frequency of the free mode gradually increases. The maximum displacement corresponds to a natural frequency of 5.4494 Hz. The main vibration forms of the coke pushing device include bending swing of the pushing rod body, torsion of the pushing head, and swing of the sliding shoe. The regions with large deformation are mainly concentrated at the tail of the pushing rod, the upper and lower ends of the pushing head, and the front and rear end faces of the sliding shoe.

In the actual field working environment, the coke pushing device operates under the support of the support rollers. To analyze the influence of the rack and pinion gear transmission system on the vibration characteristics of the coke pushing device under actual working conditions, I performed constrained modal analysis using ANSYS finite element analysis software. I applied degree-of-freedom constraints at the positions where the coke pushing device contacts the first two support rollers in actual operation. I extracted the first six constrained mode shapes.

The constrained modal analysis results for the first six modes are summarized in Table 2.

Table 2. Constrained modal analysis results for the first six modes of the coke pushing device
Mode order Frequency (Hz) Maximum displacement (mm)
1 1.5864 8.6414
2 3.4084 8.7681
3 4.3522 15.284
4 8.5461 14.874
5 10.159 17.594
6 13.321 15.202

From Table 2, I observe that as the mode order increases, the natural frequency of the constrained mode also gradually increases. The maximum displacement corresponds to a natural frequency of 10.159 Hz. The main vibration forms of the coke pushing device are bending swing of the pushing rod body and torsional vibration of the pushing head. The regions with large deformation are mainly concentrated at the pushing head and the tail of the pushing rod.

After the modal analysis, I conducted field experiments to measure the vibration of the coke pushing device. Through field tests, I found that obvious vibration occurs both when pushing coke out of the carbonization chamber and when returning from the carbonization chamber. To study the vibration characteristics of the coke pushing device, I collected vibration signal data during the entire working process at the test site.

The vibration data acquisition equipment was an INV3060S data acquisition and analysis system. The piezoelectric acceleration sensor model was INV9822. During the test, I placed the sensor on the front support roller. The measurement points were in the horizontal direction (the pushing direction of the coke pushing device), the vertical direction, and the transverse direction. The sampling frequency was 2048 Hz, and the sampling time was 130 s. I extracted the vibration signal in the vertical direction. The time-domain waveform of the vibration signal is shown in the time-domain plot. From the time-domain waveform, it is difficult to show the vibration characteristics of the pushing process and the return process separately. Therefore, I used short-time Fourier transform (STFT) to analyze the vibration signal of the coke pushing device. STFT is a commonly used time-frequency analysis method. Its computational efficiency is the highest among various time-frequency analysis methods, and the experimental results obtained by STFT have clear physical meaning.

The STFT of a signal \(x(t)\) can be expressed as

$$ X(\tau, f) = \int_{-\infty}^{\infty} x(t) w(t – \tau) e^{-j2\pi f t} dt $$

where \(w(t)\) is a window function, \(\tau\) is the time shift, and \(f\) is frequency. By analyzing the time-frequency representation, I identified two concentrated and obvious vibration regions during the entire pushing process, denoted as region A and region B. The field vibration signal acquisition process covered the entire working process from startup to completion of the pushing task and return to the original position. According to the field time record, region A belongs to the stage in which the coke pushing device pushes coke out of the carbonization chamber, and region B belongs to the return stage after pushing. Both stages show obvious vibration, and the process of pushing coke out is more severe than the return process. This is basically consistent with the vibration phenomenon observed in the field, indicating that the time-frequency analysis method can qualitatively characterize the vibration characteristics of the working process of the coke pushing device.

To study the influence of the rack and pinion gear transmission system on the vibration in these two stages, I calculated the characteristic frequencies of the rack and pinion gear transmission system using the field-measured data. During operation, the coke pushing device is driven by an electric motor that rotates the gear. The rack and pinion gear meshing transmission provides the driving force for the pushing work. Because the friction resistance that must be overcome when pushing coke out of the carbonization chamber differs from that when returning from the carbonization chamber, the motor speed differs considerably.

Through field tests, I found that during the process of pushing coke out of the carbonization chamber, the motor operating frequency is \(f_1 = 28\) Hz, and the operating speed of the coke pushing device is \(v_1 = 0.252\) m/s. During the process of returning from the carbonization chamber, the motor operating frequency is \(f_2 = 50\) Hz, and the operating speed of the coke pushing device is \(v_2 = 0.45\) m/s.

The gear rotation frequency is calculated as

$$ f_z = \frac{v}{2\pi r} $$

where \(v\) is the operating speed of the coke pushing device and \(r\) is the pitch circle radius of the gear. In my case, \(r = 0.35\) m. The meshing frequency of the rack and pinion gear is calculated as

$$ f_n = f_z \times Z $$

where \(Z\) is the number of gear teeth. In my case, \(Z = 14\).

Substituting the relevant parameters into the equations, I obtained the gear rotation frequency and meshing frequency during the process of pushing coke out of the carbonization chamber as \(f_{z1} = 0.1146\) Hz and \(f_{n1} = 1.6044\) Hz, respectively. During the process of returning from the carbonization chamber, the gear rotation frequency and meshing frequency are \(f_{z2} = 0.2047\) Hz and \(f_{n2} = 2.8658\) Hz, respectively. These values are summarized in Table 3.

Table 3. Motor operating frequency, pushing speed, gear rotation frequency, and rack and pinion gear meshing frequency
Working stage Motor frequency (Hz) Pushing speed (m/s) Gear rotation frequency (Hz) Rack and pinion gear meshing frequency (Hz)
Pushing coke out 28 0.252 0.1146 1.6044
Returning 50 0.45 0.2047 2.8658

Combining these values with the free modal analysis results, I found that during the process of pushing coke out of the carbonization chamber, the gear rotation frequency of 0.1146 Hz and the gear rotation frequency of 0.2047 Hz during the return process are both very close to the fourth-order free modal natural frequency of 0.1697 Hz. This indicates that during both the pushing and return processes, the gear rotation frequency can cause strong vibration of the coke pushing device. The maximum deformation occurs at the tail of the pushing rod, meaning that the vibration at the tail of the pushing rod is very obvious. This is basically consistent with the phenomenon observed in the field tests.

To avoid severe vibration of the coke pushing device in the field working environment, I can change the rotation frequency of the rack and pinion gear transmission system so that it avoids the fourth-order natural frequency. Although the rack and pinion gear meshing frequency during the return process is 2.8658 Hz, which is greater than the sixth-order free modal natural frequency of 2.3852 Hz, I must still closely monitor the meshing frequency to keep it away from this natural frequency and reduce the possibility of inducing severe vibration of the coke pushing device.

Combining these values with the constrained modal analysis results, I found that during the process of pushing coke out of the carbonization chamber, the rack and pinion gear meshing frequency of 1.6044 Hz is very close to the first-order constrained modal natural frequency of 1.5864 Hz. This indicates that the rack and pinion gear meshing frequency can cause severe vibration of the coke pushing device. The maximum deformation occurs almost over the entire pushing head, meaning that the vibration intensity at the head of the pushing rod is very large. This is consistent with the phenomenon observed in the field tests.

To avoid severe vibration of the coke pushing device, I can change the number of teeth of the gear in the rack and pinion gear transmission device and change the rotation frequency of the rack and pinion gear transmission system to adjust the meshing frequency so that it avoids the first-order natural frequency of the coke pushing device.

For a clearer comparison, I summarized the relationships between the characteristic frequencies of the rack and pinion gear transmission system and the modal frequencies in Table 4.

Table 4. Comparison between rack and pinion gear characteristic frequencies and modal frequencies
Modal type Mode order Natural frequency (Hz) Rack and pinion gear characteristic frequency (Hz) Working stage Possible vibration effect
Free mode 4 0.1697 0.1146 (gear rotation) Pushing coke out Strong vibration at pushing rod tail
Free mode 4 0.1697 0.2047 (gear rotation) Returning Strong vibration at pushing rod tail
Free mode 6 2.3852 2.8658 (meshing) Returning Possible vibration excitation
Constrained mode 1 1.5864 1.6044 (meshing) Pushing coke out Severe vibration at pushing head

From Table 4, I can clearly see that the rack and pinion gear transmission system generates characteristic frequencies that are close to critical natural frequencies of the coke pushing device. The gear rotation frequency is close to the fourth-order free modal frequency, and the rack and pinion gear meshing frequency is close to the first-order constrained modal frequency. These close relationships explain the strong vibration observed during both pushing and returning.

I further analyzed how changing the gear tooth number affects the meshing frequency. The meshing frequency \(f_n\) is proportional to the number of teeth \(Z\) for a given gear rotation frequency \(f_z\). If I reduce the number of teeth, the meshing frequency decreases. If I increase the number of teeth, the meshing frequency increases. For example, if I keep the gear rotation frequency at \(f_z = 0.1146\) Hz and change the number of teeth from 14 to 12, the new meshing frequency becomes \(f_n = 0.1146 \times 12 = 1.3752\) Hz. This value is farther from the first-order constrained natural frequency of 1.5864 Hz than the original 1.6044 Hz. Similarly, if I change the number of teeth to 16, the meshing frequency becomes \(f_n = 0.1146 \times 16 = 1.8336\) Hz, which is also farther from 1.5864 Hz. Therefore, selecting an appropriate number of teeth can reduce the risk of resonance with the first constrained mode.

I also considered adjusting the motor operating frequency. The gear rotation frequency \(f_z\) is proportional to the pushing speed \(v\), and the pushing speed is proportional to the motor operating frequency. Therefore, by changing the motor operating frequency, I can shift the gear rotation frequency and the rack and pinion gear meshing frequency. For instance, during the pushing stage, the motor frequency is 28 Hz and the gear rotation frequency is 0.1146 Hz. If I increase the motor frequency to 32 Hz, the new pushing speed would be approximately \(0.252 \times (32/28) = 0.288\) m/s, and the new gear rotation frequency would be \(0.1146 \times (32/28) = 0.1310\) Hz. This value is closer to the fourth-order free modal frequency of 0.1697 Hz, which is undesirable. If I decrease the motor frequency to 24 Hz, the new gear rotation frequency would be \(0.1146 \times (24/28) = 0.0982\) Hz, which is farther from 0.1697 Hz. Thus, reducing the motor frequency during the pushing stage can help avoid the fourth-order free modal frequency. However, I must also ensure that the pushing speed remains sufficient for the process.

These calculations show that the rack and pinion gear transmission system is a major contributor to the vibration of the coke pushing device. The gear rotation frequency and the rack and pinion gear meshing frequency can both excite natural modes of the structure. The vibration is especially pronounced at the pushing rod tail and the pushing head. By carefully selecting the gear tooth number and the motor operating frequency, I can shift the characteristic frequencies of the rack and pinion gear system away from the natural frequencies of the coke pushing device. This is a practical and effective way to reduce vibration.

In my study, I also examined the time-frequency analysis results more closely. The STFT plot showed that the vibration energy is concentrated in two regions. Region A corresponds to the pushing stage, and region B corresponds to the return stage. In region A, the vibration amplitude is larger, and the frequency content is richer. In region B, the vibration amplitude is smaller but still significant. The frequency components in both regions include the gear rotation frequency and the rack and pinion gear meshing frequency. The presence of these components confirms that the rack and pinion gear transmission system is active during both stages and contributes to the measured vibration. The time-frequency analysis also revealed that the vibration is not steady; it varies with the load and the motion phase. This is consistent with the fact that the friction resistance differs between pushing and returning.

To further quantify the influence of the rack and pinion gear transmission system, I computed the ratio between the excitation frequency and the natural frequency. For the fourth-order free mode, the natural frequency is 0.1697 Hz. During pushing, the gear rotation frequency is 0.1146 Hz, so the frequency ratio is \(0.1146 / 0.1697 = 0.675\). During returning, the gear rotation frequency is 0.2047 Hz, so the ratio is \(0.2047 / 0.1697 = 1.206\). Both ratios are relatively close to 1, which means the excitation is near resonance. For the first-order constrained mode, the natural frequency is 1.5864 Hz. During pushing, the rack and pinion gear meshing frequency is 1.6044 Hz, so the ratio is \(1.6044 / 1.5864 = 1.011\). This is extremely close to 1, indicating near-resonance and explaining the severe vibration at the pushing head. For the sixth-order free mode, the natural frequency is 2.3852 Hz. During returning, the meshing frequency is 2.8658 Hz, so the ratio is \(2.8658 / 2.3852 = 1.201\). This is also close enough to cause noticeable vibration.

These ratios are summarized in Table 5.

Table 5. Frequency ratios between rack and pinion gear excitation and modal natural frequencies
Excitation source Excitation frequency (Hz) Modal natural frequency (Hz) Frequency ratio Working stage
Gear rotation 0.1146 0.1697 (free mode 4) 0.675 Pushing coke out
Gear rotation 0.2047 0.1697 (free mode 4) 1.206 Returning
Rack and pinion gear meshing 1.6044 1.5864 (constrained mode 1) 1.011 Pushing coke out
Rack and pinion gear meshing 2.8658 2.3852 (free mode 6) 1.201 Returning

The frequency ratios in Table 5 clearly show that the rack and pinion gear transmission system can excite multiple modes of the coke pushing device. The most critical case is the rack and pinion gear meshing frequency during pushing, which is almost exactly equal to the first-order constrained natural frequency. This explains why the vibration is especially strong at the pushing head during the pushing stage. The second critical case is the gear rotation frequency during returning, which is close to the fourth-order free natural frequency. This explains why the pushing rod tail vibrates strongly during the return stage.

Based on these findings, I propose several measures to reduce vibration. First, I can change the number of teeth of the gear in the rack and pinion gear transmission system. This directly changes the meshing frequency. For example, if I increase the number of teeth from 14 to 15, the meshing frequency during pushing becomes \(0.1146 \times 15 = 1.719\) Hz, which is farther from 1.5864 Hz than the original 1.6044 Hz. If I decrease the number of teeth to 13, the meshing frequency becomes \(0.1146 \times 13 = 1.4898\) Hz, which is also farther from 1.5864 Hz. Therefore, either increasing or decreasing the tooth number can help avoid the first-order constrained natural frequency. Second, I can adjust the motor operating frequency. By changing the motor frequency, I can shift both the gear rotation frequency and the rack and pinion gear meshing frequency. For instance, during pushing, if I reduce the motor frequency from 28 Hz to 26 Hz, the gear rotation frequency becomes \(0.1146 \times (26/28) = 0.1064\) Hz, and the meshing frequency becomes \(0.1064 \times 14 = 1.4896\) Hz, which is farther from 1.5864 Hz. This reduces the risk of resonance. Third, I can modify the structural stiffness or mass distribution of the coke pushing device to shift its natural frequencies away from the rack and pinion gear characteristic frequencies. However, this may be more difficult and costly than changing the gear tooth number or motor frequency.

I also noted that the vibration during pushing is more severe than during returning. This is because the pushing stage involves higher friction resistance, which requires higher torque from the rack and pinion gear transmission system. The higher torque can amplify the dynamic forces at the gear mesh and the gear rotation. In addition, the pushing stage involves the interaction between the pushing head and the coke, which can introduce additional impacts and friction-induced vibration. The return stage is relatively unloaded, so the vibration is milder. Nevertheless, the gear rotation frequency during returning is still close to the fourth-order free natural frequency, so vibration is still present.

The rack and pinion gear transmission system is therefore a key component in the vibration problem. The gear rotation frequency and the rack and pinion gear meshing frequency are the two main excitation frequencies. The gear rotation frequency is typically low, in the range of 0.1 to 0.2 Hz, while the rack and pinion gear meshing frequency is in the range of 1.6 to 2.9 Hz. These frequencies fall within the low-frequency range where the coke pushing device has several natural modes. The fourth-order free mode at 0.1697 Hz and the first-order constrained mode at 1.5864 Hz are particularly important because they are close to the excitation frequencies. The sixth-order free mode at 2.3852 Hz is also relevant during returning.

In my finite element analysis, I used a detailed model of the coke pushing device. The model included the pushing rod, pushing head, sliding shoe, and support rollers. I assigned appropriate material properties and boundary conditions. For the free modal analysis, I did not apply any constraints. For the constrained modal analysis, I applied constraints at the contact points with the first two support rollers. The mesh was refined in regions with complex geometry, such as the pushing head and the sliding shoe. The results were validated by comparing the mode shapes with the observed vibration patterns. The free modal analysis showed bending and torsional modes, while the constrained modal analysis showed similar but shifted modes due to the boundary conditions. The natural frequencies from the constrained analysis were generally higher than those from the free analysis because the constraints add stiffness to the structure.

The experimental data were collected over 130 seconds, which covered the entire working cycle. The sampling frequency of 2048 Hz was sufficient to capture the low-frequency vibration of interest. The STFT used a Hanning window with a suitable window length to achieve good time and frequency resolution. The time-frequency plot clearly showed the two active regions. The frequency content in these regions matched the calculated characteristic frequencies of the rack and pinion gear transmission system. This agreement between simulation and experiment strengthens the conclusion that the rack and pinion gear transmission system is a primary cause of the vibration.

I also considered the effect of the sliding shoe and the support rollers. The sliding shoe contacts the refractory bricks and can generate friction-induced vibration. The support rollers provide rolling contact, which is smoother. However, the rack and pinion gear transmission system is located on the upper end face of the pushing rod and directly drives the motion. Therefore, its dynamic forces are transmitted directly into the pushing rod. The gear mesh generates periodic forces at the meshing frequency and its harmonics. The gear rotation generates a once-per-revolution force due to any eccentricity or imbalance. These forces propagate through the pushing rod and cause the entire structure to vibrate. The mode shapes show that the pushing rod tail and the pushing head are the most flexible regions, so they exhibit the largest displacements.

To reduce the vibration, I recommend the following actions. First, conduct a detailed study to select the optimal number of gear teeth. The goal is to ensure that the rack and pinion gear meshing frequency is at least 15% away from any natural frequency of the coke pushing device. For the first-order constrained natural frequency of 1.5864 Hz, the meshing frequency should be below 1.35 Hz or above 1.82 Hz. With the current gear rotation frequency of 0.1146 Hz during pushing, the number of teeth should be either 11 or less, or 16 or more. However, changing the number of teeth may affect the transmission ratio and the required motor torque, so a compromise is needed. Second, adjust the motor operating frequency to fine-tune the gear rotation frequency. For example, during pushing, if the meshing frequency is too close to 1.5864 Hz, I can reduce the motor frequency slightly to lower the meshing frequency. Third, consider adding a torsional damper or a flexible coupling between the motor and the rack and pinion gear to absorb some of the dynamic forces. Fourth, improve the lubrication of the rack and pinion gear to reduce friction and impact forces. Fifth, monitor the vibration continuously during operation and implement an active control system that adjusts the motor frequency in real time to avoid resonance.

In conclusion, my study shows that the rack and pinion gear transmission system has a significant influence on the vibration characteristics of the coke pushing device. The gear rotation frequency and the rack and pinion gear meshing frequency can excite natural modes of the structure, leading to strong vibration at the pushing rod tail and the pushing head. The free modal analysis identified a fourth-order natural frequency at 0.1697 Hz, which is close to the gear rotation frequencies during both pushing and returning. The constrained modal analysis identified a first-order natural frequency at 1.5864 Hz, which is very close to the rack and pinion gear meshing frequency during pushing. The sixth-order free natural frequency at 2.3852 Hz is also close to the meshing frequency during returning. These close relationships explain the observed vibration. By changing the number of gear teeth and adjusting the motor operating frequency, I can shift the characteristic frequencies of the rack and pinion gear system away from the natural frequencies, thereby reducing the possibility of vibration. This provides a practical solution for improving the working stability and safety of the coke pushing device. The combination of finite element simulation and experimental analysis proved to be an effective approach for studying the vibration characteristics of the coke pushing device and for identifying the role of the rack and pinion gear transmission system. The results can be used to guide design improvements and field adjustments to minimize vibration and extend the service life of the equipment.