POS-Based Face Gear Measurement Model

I present a high-precision solution method for the theoretical measurement model of face gears based on an improved particle swarm optimization algorithm, which I refer to as POS in this work. Face gears are a special class of gears that mesh with cylindrical involute gears and are used to transmit motion between intersecting or offset axes. They offer advantages such as smooth transmission, compact structure, low weight, and high gear ratio. With increasing applications in defense and aerospace, accurate measurement of face gears has become essential. However, the tooth surface of a face gear includes a transition surface, and its curvature varies significantly. Therefore, a reliable theoretical measurement model is the prerequisite for high-precision measurement. I establish the measurement model directly on a CNC gear measuring center, and I solve it with an improved POS algorithm. This approach avoids dependence on third-party software and improves the portability of the face gear measurement software system.

Face Gear Generation and Tooth Surface Geometry

I model the face gear as being generated by an imaginary involute cylindrical gear cutter. During generation, the cutter and the face gear rotate in a meshing motion, and their axes intersect at 90 degrees for orthogonal face gears. The cutter rotates about its own axis while a relative transverse feed motion occurs, and the face gear blank rotates about the cutter axis. This process is similar to the meshing transmission between the cutter and the face gear. The cutter typically has one to three more teeth than the mating pinion. The tooth surface of the face gear is enveloped by the involute tooth profile of the cutter end face. I describe the single-side tooth profile of the cutter in its coordinate system as

$$ r_{s}^{I,II} = \begin{bmatrix} r_{bs}\sin(\theta_{os}+\theta_s) – \theta_s \cos(\theta_{os}+\theta_s) \\ \pm [r_{bs}\sin(\theta_{os}+\theta_s) – \theta_s \sin(\theta_{os}+\theta_s)] \\ u_s \\ 1 \end{bmatrix}, $$

where \(u_s\) is the tooth surface parameter along the \(Z\)-axis direction, \(r_{bs}\) is the base circle radius of the cutter, \(\theta_{os}\) determines the tooth slot width on the base circle, and \(\theta_s\) is the involute profile roll angle. The unit normal vector of the cutter tooth profile is

$$ n_{s}^{I,II} = \pm \begin{bmatrix} \cos(\theta_{os}+\theta_s) \\ \sin(\theta_{os}+\theta_s) \\ 0 \end{bmatrix}. $$

By applying coordinate transformations according to the face gear generation principle, I convert the cutter tooth profile into the face gear coordinate system. The tooth surface of the face gear is then expressed as

$$ \begin{cases} r_{2}^{I,II}(u_s,\theta_s,\phi_s) = M_{2s}(\phi_s) \cdot r_{s}^{I,II}(u_s,\theta_s), \\ f(u_s,\theta_s,\phi_s) = n_{s}^{I,II} \cdot v_{sI,II}^{(s2)} = 0, \end{cases} $$

where \(M_{2s}(\phi_s)\) is the transformation matrix from the cutter coordinate system to the face gear coordinate system, and \(v_{sI,II}^{(s2)}\) is the relative velocity between the face gear and the cutter during meshing. The normal vector of the face gear tooth surface is

$$ n_{2}^{I,II}(u_s,\theta_s,\phi_s) = L_{2s}(\phi_s) \cdot n_{s}^{I,II}(u_s,\theta_s), $$

where \(L_{2s}(\phi_s)\) is the \(3 \times 3\) submatrix of \(M_{2s}(\phi_s)\).

During the generation process, the sweeping motion of the involute profile and the cutter tip creates a transition surface at the root of the face gear. The intersection line between the working tooth surface and the transition surface is the transition curve. This curve is the common tangent of the two surfaces and serves as the boundary between them. I determine it by the intersection between the contact line on the working tooth surface and the tip cylinder generatrix of the cutter. When the cutter profile roll angle is \(\theta_s = \theta_s^*\), the meshing equation gives

$$ u_s(\phi_s) = \frac{r_{bs}(1 – m_{2s}\cos\gamma_m)}{m_{2s}\sin\gamma_m \cos(\phi_s + \theta_{os} + \theta_s^*)}. $$

The transition curve in the \(S_2\) coordinate system is then expressed as

$$ R_g(\phi_s) = r_2[u_s(\phi_s), \phi_s] = M_{g2} r_s[u_s(\phi_s)]. $$

Theoretical Measurement Model for Face Gears

To accurately reflect the machining accuracy of the face gear tooth surface, I plan the measurement points on the working tooth surface and avoid placing them on the transition surface. Because face gears lack a dedicated measurement standard, I adopt the measurement specifications used for bevel gears. I select a fixed region on the tooth surface to represent the tooth surface error. Due to the existence of tip and root fillets, I shrink the measurement grid inward by 5% of the working tooth height in the tooth height direction and by 10% of the face width in the inner and outer end directions. This ensures that the shrinkage at the tip is larger than the tip chamfer, and the shrinkage at the root is larger than the probe radius. In the axial section, I divide the tooth surface measurement region into 9 equal parts along the face width direction and 5 equal parts along the tooth height direction, forming a \(9 \times 5\) measurement grid. This yields 45 measurement points. The grid planning is summarized in Table 1.

Direction Shrinkage Number of Divisions Number of Points
Face width 10% from inner and outer ends 9 9
Tooth height 5% from tip and root 5 5
Total — — 45

In actual measurement, the measurement coordinate system of the face gear and the design coordinate system are not unified. Therefore, I establish a measurement model that transforms the theoretical generated face gear model into the measurement coordinate system. The transformation equation is

$$ r_m = M_{2m} \cdot r_2, $$

$$ M_{2m} = \begin{bmatrix} 1 & 0 & 0 & 0 \\ 0 & 1 & 0 & 0 \\ 0 & 0 & 1 & r_{ds} \\ 0 & 0 & 0 & 1 \end{bmatrix}, $$

where \(M_{2m}\) is the transformation matrix from the design coordinate system to the measurement coordinate system, and \(r_{ds}\) is the tip circle radius of the cutter. During measurement on a CNC gear measuring center, the face gear is supported by a special fixture and placed on the rotary table. I adjust the fixture so that the face gear axis hole coincides with the rotation center of the measuring machine, making the origin of the design coordinate system coincide with the origin of the measurement coordinate system. I also keep the fixture horizontal. The probe is pre-positioned on the upper end face of the face gear and then slowly approaches the end face to determine the axial position, which I mark as the \(Z\)-axis origin.

The solution procedure for the theoretical measurement model is as follows. First, I determine the shrinkage distance in the face width direction according to the inner and outer radii of the face gear. Second, I solve the position of the transition curve based on the face gear generation principle and obtain the coordinate value of the transition curve in the tooth height direction. Third, I judge whether a transition curve exists in the tooth height direction and adjust the shrinkage distance in the tooth height direction according to the coordinate value. Finally, I obtain the theoretical measurement points on the specified measurement grid region. The solution flow ensures that all planned measurement points lie on the working tooth surface. I implement this procedure in Visual C++ 6.0, and the resulting theoretical measurement model is visualized in a CAD environment. The distribution of the theoretical measurement points shows that the iteration step along the tooth height direction must be adjusted at the small end because of the transition surface, while the step remains consistent at the large end where no transition surface exists.

Improved POS Algorithm for High-Precision Solution

Solving the theoretical measurement model of a face gear involves solving a system of nonlinear equations. I transform the nonlinear equation system into a least-squares problem and solve it with an improved POS algorithm. The objective function is

$$ M(\theta_s,\phi_s) = \frac{1}{2}\left[(\sqrt{x_2^2 + y_2^2} – X)^2 + (z_2 – Z)^2\right], $$

where \(x_2, y_2, z_2\) are the tooth surface coordinates of the corresponding point on the face gear measurement model, and \(X, Z\) are the components of the planned measurement grid region in the face width and tooth height directions, respectively. This yields a nonlinear equation in terms of the two parameters \(\theta_s\) and \(\phi_s\).

The improved POS algorithm treats the solutions of the objective function as dispersed particles distributed in the solution space. Each particle has two attributes: velocity and position. The particles continuously adjust their velocities and positions to search for the optimal solution of the objective function, which is the individual best solution. Information sharing among particles allows the swarm to obtain the global best solution. In the next iteration, the swarm uses the individual best and global best to correct the velocity and position of each particle, so that the entire population can rapidly approach the exact solution of the objective function and finally obtain the optimal solution.

I assume a target search space of \(n\) dimensions, and a swarm of \(m\) particles. The position and velocity of the \(j\)-th particle at the \(k\)-th iteration are denoted by \(X_k^j\) and \(V_k^j\). In each iteration, the particle updates its velocity and position according to

$$ V_{k+1}^j = w V_k^j + c_1 r_1 (P_k^j – X_k^j) + c_2 r_2 (P_k^g – X_k^j), \quad j = 1,2,\dots,m, $$

$$ X_{k+1}^j = X_k^j + V_{k+1}^j, $$

where \(w\) is the inertia factor, \(P_k^j\) is the individual best value of the particle, \(P_k^g\) is the global best value of the swarm, \(r_1\) and \(r_2\) are random numbers between 0 and 1, and \(c_1\) and \(c_2\) are learning factors. I use \(c_1 = c_2 = 1.82\). The inertia factor is defined as

$$ w = w_0 – 0.5\left(\frac{i}{T_{\max}}\right)^2, $$

where \(w_0\) is the initial inertia factor, which I set to 0.9, \(i\) is the current iteration number, and \(T_{\max}\) is the maximum number of iterations. This dynamic inertia weight helps balance global exploration and local exploitation.

I compared the results obtained by the improved POS algorithm with those obtained by a third-party software tool. I define the single-axis error as the absolute value of the projection of the vector between corresponding coordinates on the coordinate axes:

$$ \begin{aligned} \Delta X &= \max |X_m – X_c|, \\ \Delta Y &= \max |Y_m – Y_c|, \\ \Delta Z &= \max |Z_m – Z_c|. \end{aligned} $$

The comprehensive error is defined as the magnitude of the vector between corresponding coordinates:

$$ \Delta S = \max \sqrt{\Delta X^2 + \Delta Y^2 + \Delta Z^2}. $$

The comparison results are listed in Table 2. The maximum error in the \(X\)-axis is 0.5 μm, the maximum error in the \(Y\)-axis is 0.5 μm, and the maximum error in the \(Z\)-axis is 0.8 μm. These single-axis errors do not belong to the same measurement point. The maximum comprehensive error is only 0.9 μm. This confirms that the improved POS algorithm can solve the face gear measurement model with high precision.

Axis Maximum Error (μm)
\(X\) 0.5
\(Y\) 0.5
\(Z\) 0.8
Comprehensive 0.9

Experimental Validation on a CNC Gear Measuring Center

I conducted face gear measurement experiments using a CNC gear measuring center. The basic design parameters of the face gear are given in Table 3. I input these parameters into the face gear measurement software to solve the theoretical measurement model. Table 4 lists a portion of the theoretical measurement coordinates and their normal vectors obtained from the solution. The face gear was placed horizontally on a special fixture, and I adjusted it so that its center coincided with the rotary table center. I installed the face gear according to the pre-designed measurement model. After inputting the basic parameters into the solution program and calibrating the probe, the measurement of pitch and tooth surface errors started automatically.

Basic Parameter Symbol Value
Cutter teeth number \(N_s\) 27
Face gear teeth number \(N_2\) 81
Module \(m\) 3.3 mm
Pressure angle \(\alpha_n\) 25°
Inner radius \(R_1\) 129 mm
Outer radius \(R_2\) 149 mm
Row Column \(x\) (mm) \(y\) (mm) \(z\) (mm) \(n_x\) \(n_y\) \(n_z\)
1 1 -3.734093 -130.946770 -6.27 0.922278 -0.922278 -0.922278
1 2 -3.920857 -132.942194 -6.27 0.908879 -0.908879 -0.908879
1 3 -4.072966 -134.938545 -6.27 0.895791 -0.895791 -0.895791
1 4 -4.197832 -136.935672 -6.27 0.883031 -0.883031 -0.883031
1 5 -4.300219 -138.933467 -6.27 0.870597 -0.870597 -0.870597
1 6 -4.383474 -140.931846 -6.27 0.858483 -0.858483 -0.858483
1 7 -4.450087 -142.930741 -6.27 0.846682 -0.846682 -0.846682
1 8 -4.501991 -144.930094 -6.27 0.835184 -0.835184 -0.835184
1 9 -4.540731 -146.929853 -6.27 0.823979 -0.823979 -0.823979
2 1 -3.129342 -130.962618 -4.785 0.923382 -0.923382 -0.923382
2 2 -3.250618 -132.960270 -4.785 0.909829 -0.909829 -0.909829
2 3 -3.343649 -134.958586 -4.785 0.896621 -0.896621 -0.896621
2 4 -3.413802 -136.957460 -4.785 0.883759 -0.883759 -0.883759
2 5 -3.464716 -138.956813 -4.785 0.871237 -0.871237 -0.871237
2 6 -3.499034 -140.956578 -4.785 0.859044 -0.859044 -0.859044
2 7 -3.518771 -142.956701 -4.785 0.847170 -0.847170 -0.847170
2 8 -3.525515 -144.957134 -4.785 0.835606 -0.835606 -0.835606

I adopted measurement definitions from bevel gear standards. I define the pitch error as the difference between the actual arc length and the theoretical arc length of the midpoints of the measurement grid on adjacent tooth flanks in the same direction. The midpoint is located at the third row and fifth column. I define the cumulative pitch error as the difference between the actual arc length and the theoretical arc length of the midpoints of any two tooth flanks in the same direction. I define the tooth surface error as the projection of the actual tooth surface onto the normal direction of the theoretical tooth surface at each point, using the midpoint of the measurement grid as the reference point.

The measurement results are shown in Table 5 and Table 6. The pitch error and cumulative pitch error results show that the pitch errors on both the left and right tooth flanks are less than 20 μm. However, due to the machining error of the face gear itself, the cumulative pitch errors on the left and right flanks differ considerably. The maximum cumulative pitch error does not exceed 40 μm and exhibits a roughly sinusoidal distribution. Because the face gear has a large number of teeth, I selected three evenly distributed teeth, namely the 1st, 27th, and 53rd teeth, to measure the tooth surface error in order to improve measurement efficiency. Table 6 presents the average tooth surface error of the left and right flanks of these three teeth. The tooth surface error of the orthogonal face gear tends to increase from the midpoint of the grid toward the face width and tooth height directions. The maximum error at the small end of the left flank is 8.2 μm, and the maximum error at the large end of the left flank is -22.2 μm. The maximum error at the small end of the right flank is 9.7 μm, and the maximum error at the large end of the right flank is -14 μm.

Tooth Side Maximum Pitch Error (μm) Maximum Cumulative Pitch Error (μm)
Left < 20 < 40
Right < 20 < 40
Tooth Side Small End Maximum Error (μm) Large End Maximum Error (μm)
Left 8.2 -22.2
Right 9.7 -14

Discussion and Conclusion

I designed a theoretical measurement model for straight face gears based on the face gear machining principle and the measuring principle of a CNC gear measuring center. I selected the measurement grid region according to the actual meshing state of the face gear transmission. I planned a \(9 \times 5\) measurement grid with 45 points and ensured that all points lie on the working tooth surface by accounting for the transition curve. I implemented the solution of the face gear measurement model using an improved POS algorithm on the Visual C++ 6.0 platform. The algorithm produced high-precision theoretical measurement grid points. Compared with the solution obtained from a third-party software tool, both the comprehensive error and the single-axis errors are less than 1 μm, which proves the feasibility of the method.

I further validated the model through face gear measurement experiments on a CNC gear measuring center. The pitch error and tooth surface error measurement results were obtained. The experimental results show that the established theoretical measurement model and its solution accuracy can be applied to high-precision straight face gear measurement. The method realizes high-precision measurement and deviation evaluation of face gears and improves the functionality of the face gear measurement software system. The improved POS algorithm avoids the need for external software and enables real-time computation of the theoretical measurement model, which enhances the intelligence and portability of the face gear measurement process.

The main contributions of my work can be summarized as follows. First, I established a theoretical measurement model for straight face gears by combining the face gear generation principle with the measurement principle of a CNC gear measuring center. Second, I solved the model with an improved POS algorithm and achieved a comprehensive error below 1 μm compared with a third-party software solution. Third, I conducted measurement experiments and obtained pitch and tooth surface errors, demonstrating the effectiveness of the proposed method for high-precision face gear measurement. The method is particularly suitable for face gears with complex tooth surfaces and varying curvature, and it can be extended to other types of face gears such as helical and spiral face gears.

In summary, the high-precision solution of the face gear measurement model based on the improved POS algorithm provides a reliable foundation for face gear measurement software. It reduces dependence on external computation tools and supports the development of integrated, intelligent measurement systems for face gears. The results confirm that the proposed approach is accurate, efficient, and practical for industrial applications involving face gears.

Scroll to Top